Embedded Programming

16393 Threads Posts
to

Convert 2 digit decimal to binary in 8051

Hello everybody, I have two registers in my 8051: R0 and R1 which represent a digit decimal number. I need to convert i...
5 comments posted 21yrs
posted by gmethi
5 comments posted 21yrs posted by gmethi

Leapster L-MAX or VSmile

Does anyone have any idea what insides of the leapser l-max learning guide or VSmile consist of? their websites say the...
0 comments posted 21yrs
posted by kwebstuff
0 comments posted 21yrs posted by kwebstuff

BGA Rework/Prototype Placement Anyone?

(This was originally posted on sci.electronics.design and was intended to be cross-posted to these groups but that got...
3 comments posted 21yrs
posted by spam1
3 comments posted 21yrs posted by spam1

Crystal CS8900a dropping packets

I am running a system using the CS8900a in 8-bit I/O mode. I'm sending dummy packets to it by way of a network sniffer...
9 comments posted 21yrs
posted by bmarchio
9 comments posted 21yrs posted by bmarchio

68HC08 RKE design

Hi all, the company where I work is doing a research about RKE (remote keyles entry) HW designs, and HC08 is one of the...
10 comments posted 21yrs
posted by tanev
10 comments posted 21yrs posted by tanev

problem in thumb mode

Hi, I are facing performance related issues in my ARM project, I am using th ATMEL AT94M55800 ARM7 chip, I planned to g...
1 comments posted 21yrs
posted by anand.pavaskar
1 comments posted 21yrs posted by anand.pavaskar

Embedded FAT16 -> FAT copy handling

Hi all, I've successfully implemented a FAT16 on my CF, but i don't know how to deal with the fat copy ! When modidying...
13 comments posted 21yrs
posted by nono240
13 comments posted 21yrs posted by nono240

m16c ports

Hi All, I use m16c M30624FGPFP (24MHz) and I drive S1D13305(SED1335). If I use P5 as data port and P6 as control port E...
5 comments posted 21yrs
posted by usrdr
5 comments posted 21yrs posted by usrdr

WinCVS & CVSNT

Hi, just starting up a version control system at my company and wondered if anyone is using WinCVS & CVSNT and what do y...
5 comments posted 21yrs
posted by mr_horton
5 comments posted 21yrs posted by mr_horton

Role of Enable pin in EIA/TIA 485

Hi all, EIA/TIA 485 is an Hardware Specification, it supports both two wir and four wire mode of operation. I came acro...
3 comments posted 21yrs
posted by swizi
3 comments posted 21yrs posted by swizi

programmer recommendations?

Hi Can anyone recommend a programmer for 18F252 ? It would be nice if could be used in-circuit as well as the regular wa...
1 comments posted 21yrs
posted by bill
1 comments posted 21yrs posted by bill

Coldfire MCF5272C3

Hello, I have bought the book "Embedded Systems Firmware Demystified" by Ed Sutter. It is a nice read and I would like...
2 comments posted 21yrs
posted by caj.zell
2 comments posted 21yrs posted by caj.zell

USB 2.0 over longer distances

One of the major requirements for an inspection camera I'm designing is that it needs to be connected upto 15 meters (4...
4 comments posted 21yrs
posted by cee
4 comments posted 21yrs posted by cee