Nesto mi nije jasno: The approximate dc voltage on each side of the power supply is given by the ac rms secondary transformer rating divided by 1.414 minus 0.5. The recommended transformers have a secondary rating of 80 V AC rms. With these transformers, the power supply puts out about +58 V and -58 V
Pa zar nije ako je 80 V AC efektovni napon (jel je rms efektivni?), zar nije onda Umax = 80 * 1.414, tj 113? I kad se to ispravlja greatzovim spojem, nebi kondenzatori trebali drzat nivo istosmernog napona koji je priblizan
113?