I'm working on a box right now that uses a 250W redundant ATX supply (at the customer's request):
What's frustrating is that while this particular supply works just fine with no load on any of the rails, the manual calls for 1A minimum loads on +3.3, +5, and +12, and 500 mA on +5 standby.
This is for $$$, not a homebrew hack, so I have no choice but to follow the manufacturer's specs and bolt three big resistors to the chassis to burn almost 10W for no reason.
The other weird thing about redundant power supplies is that there is no way for the supply to signal that one of the supplies has failed. There's a loud alarm buzzer, of course, and LEDs to indicate the status of both supplies, but the power-good signal stays high when you unplug one of them, and the server motherboard has no way to know anything is amiss.
So I did hack it to the extent of replacing the status LEDs with connections to the controller. I feel like I'm overlooking something obvious here, because most of these supplies end up in data center racks that are hundreds of yards away from the nearest human. Do Google and Amazon just send somebody down the aisles every so often to listen for buzzers...?