Hi guys,
I am facing a severe design problem. I have designed a simple flasher circuit to flash a neon sign. The sign board has 5 neon transformers driving the tubes.Each transformer is rated 7500-0-7500,30mA consuming
450VA from 230V AC mains. The flashing pulses are generated by a small PIC. In my first design I used a 30A open frame relay to switch power to the 5 transformers. My ignorance about relays led to contact failure due to severe arcing in just 3 days ( sign board works for only 6 hours a day). Then I tried zero crossing firing of the relays to minimise arcing. It seemed to be ok with 2 transformers but at full load of 5 transformers it again started to arc.Fed up with relays I moved on to triac...(I had only worked on maximum 200W resistive loads with triacs). I used a BTA41 triac which is supposed to withstand 40A current. An MOC3083 was used to provide zero-crossing trigger to the BTA41. A snubber was also connected ( 0.01uF,630V and 100ohms) across the traic.A suitable heat sink was also provided. Now bingo...the flasher worked perfectly....but...not for long...It lasted 6 days:(...Can some body tell me what could have gone wrong??..or ....did I miss any crucial design aspect?...Someone please help me!!
Thanks in advance,
Rasi