"Robert Baer" a écrit dans le message de news: snipped-for-privacy@earthlink.net...
It is clear that you are more prompt to spout than to read carefully and think. I never claimed FTL propagation, but low phase shift on a _steady_ sine wave signal in a low Z driven and unterminated TL.
And before you spout again, you'd better think and/or try before.
For a 115R 100mm PCB line (660nH,50p,2.2R per meter), about 5ns/m and _fixed_ 100kHz frequency :
115R terminated : att = 0.02dB, phase = -18.5E-3 degree unterminated : att = unmeasurable, phase = unmeasurableAt 10MHz the same line gives :
115R terminated : att = 0.02dB, phase = -2 degree unterminated : att = 0.005dB, phase = -5E-3 degreeNow you can do the maths or setup a spice sim if you're lazy. In case your still too lazy I've done your homework and the results closely agree with the measurements. At 100kHz the same line gives :
115R terminated : att = 0.024dB, phase = -20.8E-3 degree unterminated : att = 17.5E-6dB, phase = 47.5E-6 degree (yes micro degree)At 10MHz the same line gives :
115R terminated : att = 0.023dB, phase = -2.059 degree unterminated : att = 5.65E-3dB, phase = -4.71E-3 degreeFor just parroting, without thinking, what you've read somewhere you've won a Burridge award.