A rather unusual question... I am looking for a way to calculate the coherence value of two signals which are several cycles of a fixed frequency sinusoidal like waveform. i.e. I need a single value in the range 0-1 for the coherence of the two waveforms.

I have tried calculating the coherence using the standard formula: |Sxy|^2 / (Sxx.Syy) where Sxy is the Cross Power Spectrum and Sxx and Syy are the AutoPower Spectrums and then extracting the value of the single frequency I am interesed in from the frequency domain response. But the coherence specturm calcuation using this technique is only valid with averaged data samples, and I only have *one* set of sampled data for each waveform, so I always get a result of 1.0 regardless of the actual coherence between the two waveforms.

Does anyone know of a way to calculate coherence, or a "coherence like" result for *non-averaged* data that gives a result from 0 to 1 for two similar sine waves?

Any help appreciated.

Thanks Dave :)

Reply to
David L. Jones
Loading thread data ...

No - I always average.

McC

Reply to
Real_McCoy

Using coherence on pure (or close-to-pure) sinusoids is usually a bad idea -- because, if the sinusoids are of the same frequency (i.e. are phase or frequency locked), they'll be "completely coherent", and if they're not they won't be.

I don't think it's because you only have one set of data, I think it's because you're only looking at one frequency --- that of the sinusoids of interest.

Start back at square one: tell us why you're really interested in the sine waves! :-)

Do they have a phase-shift between them? -> Use correlation to find it.

Do they have a frequency-shift between them? -> Mix (multiply) them and look at the beat frequency.

You'll need to supply the background before we can help further, I think.

Ciao,

Peter K.

Reply to
Peter K.

Yes, I am aware it's not the best of ideas, as coherence is usually done and calculated over a frequency domain with broadband data.

The two waveforms will in practice not be pure sinusoids, but will have minor noise and distortion components, so in theory a coherence calculation is possible. In fact, the goal is to have them as completely coherent as possible (as it is for most systems) i.e. no noise or distortion is added to the system, and all of the output signal is due entirely to the input signal.

No, it's the same over the entire frequency domain. The standard coherence function as presented relies on averaging. If you have calculate coherence with no averaging you get a result of 1.0 in every frequency bin. This is why every dynamic signal analyser will not allow you to display coherence without turning on averaging.

For mostly political reasons (don't ask!) I require a "coherence" number of 0 to 1 to indicate the "quality" of one waveform compared to a reference. The standard way to do this is with a coherence function, but in this case I do not have the averaged data sets available to do this usign the standard technique.

In the end I may have to compare the signals in the time domain instead of using the coherence function in the frequency domain. I have a way to do this to give a 0 to 1 "coherence like" number, but I am wondering if anyone knows how to do it in the frequency domain using a coherence function?

I know there are many other ways to compare two waveforms, but I need a

0 to 1 "coherence" indication display.

Dave :)

Reply to
David L. Jones

Try Average Cross-Correlation R12(t) = (Integration sign from -infinity to +infinity) v1(t)*v2(t)*(T+t)dt This is for non-peiodic waveforms. reference: Principles of Communication Systems - Taub+Schilling

Alan

Reply to
Alan Peake

Thanks Alan. My waveform will however be periodic, several full cycles of fixed frequency data. So probably not suitable?

Dave :)

Reply to
David L. Jones

OK.

So the outcome you'd like is for the "coherence" to be 1.

OK. That's a little strange, but perhaps you're right about the averaging... though I'm not exactly sure what you mean.

Dumb question: why can't you just block the data you have into, admittedly smaller, datasets so you _can_ use the averaging technique?

That's what matlab does: if I do this:

x = sin(0.090823*[0:1023]+rand(1)*2*pi) + randn(1,1024); y = sin(0.090823*[0:1023]+rand(1)*2*pi) + randn(1,1024);

and then try

cohere(x,y,1024)

everything is 1, but if I go

cohere(x,y,128)

I don't get the frequency resolution, but I do get something that's 1 around the right frequency and not 1 outside of that.

Bear in mind that this example is very fake: even with random phases, the freqyencies are effectively "locked".

OK. Ain't politics a killer? :-)

Total harmonic distortion (THD)? That'll start at zero and probably never get close to 1. If you need "good" to be close to 1, how about: 1 - THD?

Thanks for taking the time to explain more about the problem.

Let us know if any of this is a help.

Ciao,

Peter K.

Reply to
Peter K.

In Matlab

coh=rand;

;)

Reply to
Stan Pawlukiewicz

:-)

Ciao,

Peter K.

Reply to
Peter K.

Yep. That is the desired outcome for any measurement system, which is why coherence measurement is of such importance, especially in the vibration and acoustics systems I am involved with.

Unfortunately I don't have the necessary math skills to explain it, but the coherence function is inherently meaningless if you don't do it over averaged data. Your Matlab example below shows that the result is

1 for all frequency bins, and that is exactly my problem too. If you are interested, this might explain it a little better:
formatting link

Yes, I thought about this, but I don't think I have sufficent data to do this. I'm already getting 10Hz frequency bins on the output of my FFT power spectrum functions, and the signal I want to measure is 40Hz. Not exactly crash-hot resolution :-( Also, I might only have several cylces in total to work with (it is user selected in software). In fact, in some cases I might only have 1 cycle to work with, so my coherence calculation function might have to handle that eventuality too.

The #1 killer of every cool project!

Gave that a brief thought, but I suspect it may be be a bit "touchy" and not robust enough. I would actually need a THD "envelope" pass/fail band as my two signals may (or may not) have significant THD, but have still perfect coherence. Not sure how you would scale that to a 0-1 result either...

In any case, I've already got a time domain analysis method in mind that will work, based on scaled means and error difference between the two waveforms. I just have to go through the motions to eliminate the possibility of any other frequency domain coherence method.

Thanks for your help Peter. It is good to know that Matlab gives the same result I am getting in my LabWindows/CVI software.

Regards Dave :)

Reply to
David L. Jones

In Labwindows/CVI: coherence=Random(0.8,1.0);

Tempting, very tempting! ;-)

The stupid thing is, I could most likely get away with it, having just shifted our managerial focus to being "results driven"!

Dave :)

Reply to
David L. Jones

You poor b*st*rd! :-)

Ciao,

Peter K.

Reply to
Peter K.

It's ok, it'll change again next month, regular as clockwork!

Dave :)

Reply to
David L. Jones

Hi David,

It seems that it is unecessary to go to the frequency domain for this problem, since all you want to do compare time-domain images of short duration. As you probably discovered, you get impulses in the frequency domain for signals of low spectral variance.

One way to calculate the "coherence" in the time domain for short-duration signals is:

  1. take the time-domain samples of two signals and treat them as vectors in N-space.
  2. Normalize each vector so as to kill any power advantage that one might have over the other. They will retain their positive and negative components.
  3. Take the scalar product between X & Y to yield a value from -1 to
+1.
  1. Shift the scalar product +1 to get value between 0 and 2.
  2. Divide result by 2 to get value between 0 and 1.

If you prefer, you can avoid steps 4 and 5, so you could end up with confidences of

+1 = strongly correlated 0 neutral

-1 strongly uncorrelated

Naturally, the hills and valeys will dominate the output of the correlation if you use this, so if you are really interested in phase/magnitude correlation, you can do something similar:

  1. Normalize both signals (before or after DFT - after relieves any cofactor fuzzies in FT)
  2. Take DFT
  3. Treating phase and magnitude separately, take scalar products to yield -1 < x > +1.

But again, for signals that are both in phase with same spectral content, you should not be surprised to get something very close to 1 on both accounts, as the frequency domain will contain weak noise dominated by impulses convolved with sin(x)/x.

-Le Chaud Lapin-

Reply to
Le Chaud Lapin

Have you looked at one of the Bendat and Piersol books, like Random Data? Most of the stuff they do is vibration analysis and I do recall they cover coherence in some detail.

Reply to
Stan Pawlukiewicz