SONY DCR-TRV520 Fault Solved!

I finally determined the LCD display fault was being caused by movement of the LCD panel, but I could not get any sort of correlation between the movement of the panel and the display fault. I decided that somehow, pressure was being applied inside the LCD panel to the membrane switch for volume. I removed the 4 screws and took off the LCD panel outer cover. I blew out the circuits and rearranged the ribbon cables slightly. I really couldn't see any fault, but after reassembly, the display fault has disappeared, and the camera functions normally. YAAAAAAYYYYYY! JR

--
--------------------------------------------------------------
        Home Page: http://www.seanet.com/~jasonrnorth
Reply to
JR North
Loading thread data ...