true RMS meter vs. oscilloscope

In article , wrote: : :Which waveform has the greatest discrepancy between average and rms values?

Presuming that you're thinking of unipolar waveforms, that would be a train of narrow rectangular pulses rising above a zero baseline. The ratio of average to RMS is the square root of the duty cycle, so the ratio Vrms/Vavg goes toward infinity as the duty cycle approaches zero.

--
Bob Nichols         AT comcast.net I am "rnichols42"
Reply to
Robert Nichols
Loading thread data ...

The best "cheap commercial RMS converters" are ICs that do a superb job, and i think some get fairly close to what NIST does.

Reply to
Robert Baer