Re: Help with Zilog180 ASCI on COM1

Hi all,

> > I got thrown into a project that has Zilog 180 onboard. I am trying to > make this device communicate with PC using the famous 3 wire serial > cable. But, I am having so many Overrun Error (OVRN) and Framing Error > (FE) problems. Even at 300 baud at 2 stop bits. The processor is clocked > with a 4.608 MHz Oscilator and I am using the ASCI Baud Rate Selection > Table (on Z180 PDF) for choosing speeds. > > The hardware designer is not around anymore, and I can not get any other > help. Line driver is ADM232LJN. > > Are there any know issues with communication with Z80 or Z180.

Not at all regarding speed. I have and still run Z80 systems clocked on

6.144MHz, running 2 uarts; one on 19200 baud, the other at 96000 baud.

If you have framing errors and/or overruns, check the data format (7/8 bits, parity, no. of stop bits).

Meindert

Reply to
Meindert Sprang
Loading thread data ...