frame fault TV HITACHI CP-2892TAN chassis SCHNEIDER DTV101

I'm trying to fix this 100hz Hitachi set which uses a schneider chassis. problem is there's only half a raster - the lower half is good, then there's a bright horiz. line typical of sets with frame collapse, and above that nothing. Could the frame chip be bad or is there something else to look for before changing it...it's a TDA8177 I think. I've changed the 33uF 100v cap near it to no effect.

-B

Reply to
b
Loading thread data ...

....me despist=E9 cone el idioma! ahora viene la traducci=F3n ;-)

este tv tiene s=F3lo la parte de abajo del im=E1gen; en la parte de arriba no hay nada. hay una raya horizontal t=EDpico de los aver=EDas de vertical. ya he cambiado el electrol=EDtico de 33uF d=F3nde el c.i. vertical (un tda 8177 creo); ahora no s=E9 si cambiar el integrado o si hay algo m=E1s que debo mirar o que suele fallar en estos tv.. gracias de antemano. B

Reply to
b

a

al final cambi=E9: el TDA 8177

2x 1000uF, 16 electrol=EDticos 1x 33uF electrol=EDtico

...y parece estar solucionado.

un saludo. B

Reply to
b

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.