Pwr Supply Problem

I made a power supply with 3 paralelled LM338 Regulators in paralell (24V 12A trans), with 2 paralelled 20A rectifirs, worked great for 1 week, then all of a sudden, output dropped to 2 amps max (from 15A), , all componed seem to check out ok, getting full current out of filter caaps past rectifiers, any ideas, tried substituting a good regulater, and same thing, any ideas.

Reply to
scott93727g
Loading thread data ...

I have mostly questions, but first a couple of points: First, your transformer current rating needs to be about

1.5 - 1.8 times greater than the maximum current you will draw. You didn't say what that is. Why did you put rectifiers in parallel? That doesn't give you the equivalent of a 40A rectifier - I assume you thought it might.

Ok, now to the problem. How do you balance the current drawn from each LM338? Schematic please. How did you test that you are getting full current out of the filter caps past rectifiers, and what is "full current" - how many amps? Are your LM338's installed on heat sinks? How much current do you want to be able to draw?

Ed

Reply to
ehsjr

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.