Neophyte Question: measuring open circuit voltages

Dec 15, 2005 1 Replies

Hi,



I'm trying to measure the voltage induced by a peizoelectric cable (applying pressure to cable creates voltage/current on cable). But when I measure the voltage across the cable I get a "background" signal that looks like an exponentially decaying voltage, like a large capicitance discharging. I can measure the real voltage across the cable, it appears on top of the decaying voltage, but soon the voltage reaches what I assume is the max low value for my board (National Instruments, BNC 2120, floating point measurement), -10 volts. I can get the voltage to go back to zero by touching the leads but this just sets the process in motion again. This decaying voltage characteristic is also present when nothing is connected to the leads, which makes sense, hence my question about measuring open circuits. Needless to say I would like the voltage of an open circuit, or accross my cable to be



  1. How can I make this happen?

Thanks in Advance.



Your NI board input circuitry has a bias current, probably in the nanoamp region, which is charging up the cable. You could try injecting a current from a stable DC voltage of opposite polarity through a *very* high value resistor, adjusting the voltage and resistor until the voltage on the cable is nearly constant. Then flex the cable and take your measurements quick like a bunny.

Or, get one of these:

formatting link

and use it as a buffer to get the input current down to the femtoamp range. You then momentarily short the leads to reset the voltage to zero, and the bias current of the LMC6001 will charge the cable so slowly that you should be able to get your measurements.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required