Dec 31, 2005 4 Replies

You can't tell unless you know what the resistance is. If you know the resistance, then

V(t) = Vo * exp(-t/R/C)

and

I(t) = V(t)/R

so

I(t) = Vo * exp(-t/R/C) / R

where Vo is the initial voltage across the caps.

If you can measure how long it takes for your voltage to get down to 1/2 the original voltage, you can figure out the resistance; it will be

R = t/(ln(2)*C)

plug that back into the I(t) expression.

For example, if it takes 0.1 second to discharge down to 2.5 volts from a

5 volt charge, then

R = 0.1/(ln(2)*.75) = 0.192 ohms

Then, the initial current will be I = 5/0.192 = 26A, and after 0.1s, will be 13A.

Regards, Bob Monsen Our minds are finite, and yet even in those circumstances of finitude, we are surrounded by possibilities that are infinite, and the purpose of human life is to grasp as much as we can out of that infinitude. - Alfred North Whitehead

Not necessarily, Most SCRs can withstand at least 10 times their rms current rating in a discharge application such as this. If you have the data sheet look at the peak one cycle surge current rating

what's the resistance and inductance of the whole setup? (the limiting factor is probably the resistance of the capacitors)

Bye. Jasen

Is there a way to calculate the amps a capacitor dischages through a short?



I have a "spot welder" made up of five large 150,000 uf (5 volt)computer capacitors in parallel, which are charged to up using a 1 to 5 volt supply and dischaged through a SCR to 2 beefy probes. The purpose is to spot weld terminal tabs on batteries in place of soldering them on.



How many amps are being produced across the terminal probes, ususally spaced



5mm or so apart? Is there a math formula to calculate this? My 70 amp SCR still survives, so I guess it must be less that that.

thanks Jim


Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required