UIC option in SPICE?

I have read all I could find about the Use Initial Conditions (UIC) option in SPICE, but I still don't fully understand it. The reason I am confused is this: When I run a DC transient analysis with UIC enabled on a simple RLC tank circuit (with all passives having an IC of '0'), shouldn't these results be the same as a DC transient simulation with *no* UIC, since they should both have a initial starting condition of 0V/0A? Yet with the simulation with no UIC enabled, the circuit reaches steady state instantly; while with the UIC option enabled it takes a finite time to reach its voltage level, then over/undershoots a few time (rings) -- as it should. What am I missing here?

Thank You,

-Bill

Reply to
billcalley
Loading thread data ...

Have you read:

formatting link

?

Charles.

Reply to
Charles DH Williams

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.