UIC option in SPICE?

Jun 23, 2005 1 Replies

I have read all I could find about the Use Initial Conditions (UIC) option in SPICE, but I still don't fully understand it. The reason I am confused is this: When I run a DC transient analysis with UIC enabled on a simple RLC tank circuit (with all passives having an IC of '0'), shouldn't these results be the same as a DC transient simulation with *no* UIC, since they should both have a initial starting condition of 0V/0A? Yet with the simulation with no UIC enabled, the circuit reaches steady state instantly; while with the UIC option enabled it takes a finite time to reach its voltage level, then over/undershoots a few time (rings) -- as it should. What am I missing here?



Thank You,


-Bill



Have you read:

formatting link

?

Charles.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required