No phase shift filter

Dec 09, 2006 22 Replies

Digital filters can easily give you zero phase shift. Because they are trivial to implement negative time.

Intro at

formatting link
and more recent.

Many thanks, Don Lancaster voice phone: (928)428-4073 Synergetics 3860 West First Street Box 809 Thatcher, AZ 85552 rss: http://www.tinaja.com/whtnu.xml email: don@tinaja.com Please visit my GURU\'s LAIR web site at http://www.tinaja.com

In article , Don Lancaster wrote: [....]

This is only true if you ignore the fact that they must be applied to the data after it is gathered. You can't do it in real time.

-- kensmith@rahul.net forging knowledge

If you're willing to move the time origin, you can add as much linear phase shift of either sign as you like. The reason for sticking with normal time is that all the useful causality conditions depend on that definition. I invite you to use your 'negative time' to stabilize a feedback loop.

Cheers,

Phil Hobbs

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required