Measuring Retun Loss

Jan 22, 2007 1 Replies

Hi All,



I would like to do some return loss calculations using LTSpice Spice, using the Wheatstone Bridge Method.



Eg this Wheatstone circuit here

formatting link



Return Loss in terms of source an load impedances is defined here

formatting link



However , return loss can be measured using the Wheatstone Bridge method and measuring voltages accross the bridge to compute the Return Loss. (may be similar to this circuit

formatting link



This is for POTs Telecom Impedance circuits 0 ~ 4kHz where the reference impedance may be complex or 600R



QUESTION Can any one suggest a simple Wheatstone circuit where I can measure voltages to compute the return loss - source against load impedance.


Thanks in advance



Joe


Yes, lets assume a 50 Ohm system

You feed your circuit under test from a swept voltage source through a

50 ohm series resistor that creates the proper source Z for the generator. Set the Voltage source to 2 Volts. Call the junction of the 50 Ohm resistor and your circuit node 2.

Now when your circuit exhibits the correct load Z of 50 Ohms, there will be 1 volt at the junction node 2.

Now you connect a divider consisting of 2 equal resistors (any value will work in simulation ) also to the voltage sounce. And the junction of the two divider resistors you call node 99. This node is also 1 volt. So now you just have to measure the voltage DIFFERENCE between node A and B and express it in dB and this is your return loss.

i.e.

Trace Add DB(V(99)-V(2)) OK

this will work for any Z system, just change the first series resistor to the correct value...

Mark