just
See
t is not the same as sweeping a source. For that he wants. .dc dec I1 100p
100m 10 which DC sweeps current I1 logarithmically from 100pA to 100mA with 10 steps per decade. This generates a single curve. Your ridiculous comman d would produce a gazillion curves.Almost as useless as this one, which at least illustrates difference in use of sweep and step.
Version 4 SHEET 1 880 680 WIRE 384 48 240 48 WIRE 240 96 240 48 WIRE 144 144 96 144 WIRE 176 144 144 144 WIRE 384 176 384 48 WIRE 240 224 240 192 WIRE 96 320 96 144 WIRE 240 320 240 304 WIRE 240 320 96 320 WIRE 384 320 384 256 WIRE 384 320 240 320 WIRE 240 336 240 320 FLAG 240 336 0 FLAG 320 32 IC FLAG 144 144 IB SYMBOL npn 176 96 R0 SYMATTR InstName Q1 SYMATTR Value 2N3904 SYMBOL current 240 224 R0 WINDOW 3 24 28 Left 2 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR Value 100p SYMATTR InstName I1 SYMBOL voltage 384 160 R0 WINDOW 123 0 0 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V1 SYMATTR Value 0.5 TEXT 392 72 Left 2 !.dc dec I1 100p 100m 100 TEXT 392 112 Left 2 !;.temp -25 0 25 50 100 150 TEXT 400 24 Left 2 !.op
Must be no temp dependence in the NPX 2n3904 model because it doesn't budge . Technically you just add and select I1/Ib(Q1)-1 in Visible Traces box. The heap of junk doesn't respond to the plot directive. Heck it doesn't even ge t the horizontal scale right half the time, tries to take log of 0. Then it intermittently hangs during the simulation but runs fine other times. Dunn o who uses this program.