Floor Temperature

Jun 11, 2008 24 Replies

I'm with Phil here.. a hole drilled into the concrete to accomodate the sensor will yield solid readings. Other methods are unlikely to do so.

Best regards, Spehro Pefhany

"it\'s the network..." "The Journey is the reward" speff@interlog.com Info for manufacturers: http://www.trexon.com Embedded software/hardware/analog Info for designers: http://www.speff.com

...

Well, the ends of either the heater wires or the heat tubes are right there at the power supply - either put the heater in a bridge and control it that way; if it's a liquid we need more information - for example, could you slide a thermistor up the line, catheter-style?

Good Luck! Rich

This is a non-starter - he wants to heat the concrete _before_ it freezes.

Hope This Helps! Rich

Or wet the floor and crank the heat up; the places where the lines are will dry first.

That'll do the trick. The OP might want to include an insulating layer over the top of the sensor to keep it from being influenced by air temperature. Then, just glue the whole shebang down.

Paul Hovnanian mailto:Paul@Hovnanian.com ------------------------------------------------------------------ Opinions stated herein are the sole property of the author. Standard disclaimers apply. All rights reserved. For external use only. If irritation, rash or swelling occurs, discontinue use immediately and consult a physician. Void where prohibited.

Join the Discussion

Have something to add? Share your thoughts — no account required.

Didn't find your answer?

Ask the community — no account required