-and-
Your equation is based upon the amplifier open circuit voltage, Voc, and the effective output resistance, Ro, taking the load current as the circuit phasor reference angle so that Voc/_phi1,2=I1,2*(Ro-jXc)+E1,2 for the two different load conditions, R1,2. Note that phi1 is not equal to phi2, only Voc amplitude stays constant with loading. The so-called output impedance is *always* the coefficient of the I term which is Ro-jXc and has nothing to do with R1 or R2 assuming the circuit stays linear. Since the Voc phase angle changes, your only option is to work with scalar magnitude or magnitude squared in I1 and I2, the reference, so this gives you I1^2*((Ro+R1)^2 + Xc^2)=I2^2*( (Ro+R2)^2 + Xc^2) as the only recoverable equation given your measurements. This develops into Xc=sqrt{(I1^2*(Ro+R1)^2-I2^2*(Ro+R2)^2)/(I2^2-I1^2)}. Plugging in your measurements R1=600, R2=300, Ro=10, I1=14.81/600, I2=14.50/300, yields Xc=600*sqrt{(14.81^2*(1+10/600)^2-14.50^2*(1+10/300)^2)/(4*14.50^2-14.81^2)} or Xc=600*sqrt{2.2079523/(621.6639)}=600*0.059596=36 ohms so that C=1/(36*6.28*400)=11uF and not 5.6u- this is suspiciously a factor of x2. Also, the output impedance is 10-j36 or 37 ohms reactive.