Marshall MG100HDFX ,2002

Loss of clean channel intermittently, dirty channel ok. Both clean switches have no contacts made in clean mode. I'll replace the clean vol control, but nothing obviously wrong. No obvious solder problems in that area. Anyone know if anything of the clean ch,separately, goes through the digital effects pcb.? 3 pcb fixings only on 3 of 4 corners, allowing one corner to lift with vibration, the header side. I'll reset pins and fit a cable tie over that corner (too populated to have a 4th fixing) When I can repower I'll remove the dsp board and see what that does

Reply to
N_Cook
Loading thread data ...

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.