Latest threads in Electronics Equipmentshow only best voted threads

Subject Author Posted Replies
 
Vertical and Horizontal Sync Rate for a HDTV Philips 32PF9631D
Hello, I'm using this LCD TV (aPhilips 32PF9631D) as a monitor (OS=Linux) For the moment I've got 1024x768 pixel resolution I wish to get a 16/9 format (1360x768). For that I need to know this...
 
Front end for Spectrum Analyser
Hi, I have a spectrum analyser (Siemens K2001)but alaas it's only for a limited band (200Hz to 4200Hz) I intend to use it for low frequencies Up to 100KHz. My question is it done in commercial...
2
2
 
ADRET 740 signal generator
Hello, The french compagny that made this signal generator ist out of business for a long time. I need a spare CPU card and cannot find it thru search engine; any suggestion ? thank you.
1
1
 
HP 8660C synthetized signal generator
Hello there, Is there anybody that is familiar with the use of this signal generator ? I got one thru eBAY and it seems not to work properly as I can't get any signal out @ the 86603A RF section....
2
2
 
Tektronix A6302 and P6302 current probes
Hi, I=B4m considering buying one of these on ebay. These 2 products seem identical. Does anyone know what the difference is? Thanks
2
2
 
Efratom MRT service manual.......
EFRATOM type MRT. I'm looking for a service manual. Thanks. maurizio
 
"Vampire" wattmeter
Hi... I saw a piece on CNN about how much power household electronics can consume on "standby". In it, Alan Meier of the Lawrence Berkeley National Lab was using a really neat little digital wattmeter...
9
9
 
Testing a Multimeter
Hello all, I am looking at buying a used Fluke multimeter (either an 8060A or a 77-III) from a local guy and I would like some simple tests I can do on each meter. Neither meter has a current...
1
1
 
A6302 currentprobe - Ideas on how to find problem?
Hi, I have A6302 Tektronix current probe that shows erratic behaviour. The overload light is on, and its intensity varies depending on how open the probe is. The DC offset is way off, AC output is...
2
2
 
Stuck channels on a 16550A
I have a 16550A with several stuck channels. One of them is always stuck hi and two other stuck low. I checks the cables on another card and they work fine. When I boot the 16500B into diagnostic...
3
3
 
FA: RACAL DANA 9919 UHF FREQUENCY COUNTER
RACAL DANA 9919 UHF FREQUENCY COUNTER MEASURES 10 Hz to 1.1 GHz. Has extremely stable Time Base and works to spec. Take a look: Thanks, Dick, W1KSZ
 
FA: HP 83572B SWEEPER PLUG-IN 26.5 - 40 GHz
Full Waveguide Band Sweeper Plug-In for the HP 8350A/B Mainframe. I had it checked out and it works as it should. Take a look: Thanks for looking, 73, Dick, W1KSZ
 
Advantest R3261A service manual
Hi, my Advantest R3261A spectrum analyzer has a fault in its PSU and I'm looking for a service manual. Even a scan of the PSU part will help a lot.
5
5
 
precision Agilent Measurement Device for auction
3
3
 
How bypass test fails Tek 2245?
Can anyone tell me how to get a Tektronix series 24xx oscilloscope to operate even though several of the power up self-tests "fail" on screen? I am assuming there is a bypass button somewhere. Of...