Lets say we have a nice windy and sunny day and some discharged batteries. Lets say 11V. I hook up the pv charge controller, its putting out whatever V it thinks is getting max power. Lets say its

14V. Now the microcontroller on the wind turbine charge controller sees 14V, and either thinks the battery is charged, or tries to hump out 16V or so to try to get some amps into the rig, but this would confuse the mppt pv controller. So is there an algorithm or strategy for using two different charging sources at the same time? Have two big watt low ohm mixing resistors, like mixing audio? Heating Rs doesnt sound thrifty.
Reply to
BobG
Loading thread data ...

You are describing more than one issue. Yes you can charge a battery from multiple sources provided the sources are isolated from each other. In you example a simple diode would most likely do the trick. The individual regulation of each charging system would be a function of that system. You may also need to supply a sense signal to the chargers separately. Tom

Reply to
Tom Biasi

Sense the two currents, and design a controller that will adjust them both to share the load. You'll have to come up with an algorithm, but conceptually it's like a mixer - two inputs and one output. You know what the output needs, and each of the inputs has a certain capacity. You could run them both wide open and just limit them by looking at its input current vs. the output spec, and send it a "not so much" signal. You'd do that to the other one simultaneously, and you'd have to decide how you want to write the algorithm (or design the circuit =:-O ) to do the sharing the way you want it.

Then again, you could just run the solar wide open (as long as it's voltage-limited) and regulate the charging current from the windmill, either by feathering the blades, or finding someplace else to dump the power, like into the house or the grid. ;-)

Of course, you'd need to include the charge controller, to say "OK, Enough!" when it is. Then you'll have to just let all of that energy lie there. )-; Or get more batteries for Xmas. ;-)

Have Fun! Rich

Reply to
Rich Grise

--
If you have two sources which are both capable of charging your
batteries, and they\'re both hot, and you know the maximum charge
current allowed into your batteries, choose the source which will
waste the least energy.
Reply to
John Fields

If these are lead acid battery controllers, then the controllers will probably first try to limit current, then maintain a constant cell voltage. After this, they may or may not drop the voltage a bit for a 'float' phase.

If you use both through diodes, and they both measure the current separately, then you'll end up with twice the current, which could overheat the battery. After they charge the batteries too quickly, they will then attempt to keep the voltage too low, because of the diode drop on the output. So, it'll work, but not very well.

If your controllers could measure the total current rather than their contribution, then they would be able to share the load. If they measured voltage at the battery, rather than at the output of the controller, they could also deal with the saturated phase of charging properly by decreasing the current to maintain the voltage. I'm not sure how this would work for the float phase.

To make this work, you would probably need to figure out how the controllers measure current and voltage, and manipulate the inputs somehow. Having a single controller that handled all of this would be the optimal solution.

These guys claim to have figured it out:

formatting link

Regards, Bob Monsen