SS Relay causing failure of induction motors?

I have installed a thermostat in my garage to control a fan placed on a she lf in front of the peak vent. The thermostat box has a 6V AA battery pack w hich switches control voltage to SS relay near the fan. The relay says "Sil icon Power Cube" on it and is rated for 240V and 3A. I am using it on 120VA C. The control voltage is specified at 3 to 32 VDC. This system works perfe ctly. I have been using common 20 inch box fans. The problem is they only l ast a year or so and then they just stop working. Sometimes they fail over the winter when they never run. I have tried to troubleshoot the fans but c an't find out why they have failed. The capacitors on the motor measure th e correct value. I suspect there is something in the SS relay that is causi ng them to fail but I have no idea how. Are SS relays compatible with induc tion motors? I am on my fourth fan in about 5 years now and these fans usua lly last forever. Thanks for any ideas. Soartech

Reply to
Deane Williams
Loading thread data ...

then they just stop working. Sometimes they fail over the winter when they never run. I have tried to troubleshoot the fans but can't find out why they have failed. The capacitors on the motor measure the correct value. I suspect there is something in the SS relay that is causing them to fail but I have no idea how. Are SS relays compatible with induction motors? I am on my fourth fan in about 5 years now and these fans usually last forever.

If you are refiring to the generic cheap window fans you get in the store, I find for the most part, they only last a year anyway..

You must check to see how stiff the rotor is, many times the bushings will dry out from the heat. Also after some run time the bushings will loosen up and when this happens, dust in the area will migrate its way into the bushings, what you normally end up with is a fan that worked last year but now is having a hard time starting, due to drag.

These box fans operate hot anyway, due to their design.

You may want to think about getting a real vent fan for agricalture, a motor type design to last in plases like chicken coops etc...

P.S. Shop around at your local hardware store with a vent fan with this type of motor on it.

Jamie

Reply to
M Philbrook

Jamie, Thanks but I believe the problem is electrical. The fans still turn easil y with little or no drag after they have stopped working. Two years ago I b ought a higher quality fan from Home Depot and I thought I had solved the p roblem as it lasted through 2 summers, but this year it only ran a couple o f days and then failed in the same mysterious way as the cheap box fans. Even stranger, I went out and bought my 4th fan at Home Depot which looks v ery similar to the one I had and when connected to the SS relay it won't ru n. It just sits there and hums. So I put it on a timer which is not as good as a thermostat.

Reply to
Deane Williams

THat's perhaps a clue that your SS relay is defective and only switching one polarity of the line. So you get DC, the fan hums and doesn't turn, then the motor burns out if left connected.

One kludge but effective solution would be to have the SS relay control an AC/DC relay that switches the fan.

--
    sam | Sci.Electronics.Repair FAQ: http://www.repairfaq.org/  
 Repair | Main Table of Contents: http://www.repairfaq.org/REPAIR/  
+Lasers | Sam's Laser FAQ: http://www.repairfaq.org/sam/lasersam.htm  
        | Mirror Sites: http://www.repairfaq.org/REPAIR/F_mirror.html 

Important: Anything sent to the email address in the message header above is 
ignored unless my full name AND either lasers or electronics is included in the 
subject line.  Or, you can contact me via the Feedback Form in the FAQs.
Reply to
Samuel M. Goldwasser

For testing purposes, connect a drop light with a incandescent bulb in it on the same circuit that runs the fan after the SSR. You may only need a small one. See if the fan will operate with that light also connected to the same circuit, use a power strip of something that gets powered via the SSR to make sure you're on the same switched circuit.

Report back :)

Jamie

Reply to
M Philbrook

Some SSRs are not happy with largely inductive loads (i.e. fans).

Isaac

Reply to
isw

These fans have one-time thermal fuses buried in the windings, to prevent house fires. If you are using this to cool off a hot attic, that may be getting the thermal fuse too close to the fusing temperature, add a couple hours of motor on time and the fuse may blow.

Jon

Reply to
Jon Elson

You might try a name brand solid state relay and see what happens. Crydom is real, silicon cube is not.

Reply to
Cydrome Leader