Got a call on a Sony Model # KP-43T75, had a blue halo around objects in the pix, now it's dead. Are these sets known for bad CRT's? If so, do the CRT's kill the set? Thanks, Dani.
- posted
16 years ago
Got a call on a Sony Model # KP-43T75, had a blue halo around objects in the pix, now it's dead. Are these sets known for bad CRT's? If so, do the CRT's kill the set? Thanks, Dani.
Get a better description of "halo" from your client. That description could be anything from convergence to focus issues to CRT coolant. Most common would be convergence outputs, but I would not descrivbe the symptom as a halo.
I have not seen bad CRTs in this model.
Leonard
Why don't this asshole just have his client draw you a picture of it, asshole?
Go suck a dick in prison.
Check the pico fuses on the "G" power board and on the "D" deflection boards. If either of the 5 amp are blown on the "G" board then you are fairly certain the STK devices on the "D" board are failing. Then check the
ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.