High voltage safety precautions

Hi,

I'm going to do some experimentation on high voltage equipments ( transformers, power supplies, capacitor banks, lasers , etc.. ).

Does anyone know where I could find some safety guidelines or notes about working with this dangerous stuff ?

( I wouldn't like to die because of a spark jump and make my wife a widow... )

Thanks

Stef

Reply to
ragno.stefano
Loading thread data ...

Oh, brother. Do her a favour and take up welding instead.

Cheers

Phil Hobbs

Reply to
Phil Hobbs

Wonder what his wife's take on this experiment is? Maybe she's all for it?

Reply to
PeterD

Two deathly dangers - one from actual electrical shock, one from impaling yourself on something sharp when you jump from the shock and bleed to death

Reply to
hrhofmann

On 05/04/2009 04:52 AM, snipped-for-privacy@gmail.com sent:

Hello Stef:

Please define the levels of high voltage you are referring to.

Laser safety is also an entirely different subject. What type & class laser?

Pete

--
1PW  @?6A62?FEH9:DE=6o2@=]4@> [r4o7t]
Reply to
1PW

Heh. The second point is the one that tends to catch telco tech's when the phone rings while they're working on the MDF. ;^)

--
    W
  . | ,. w ,   "Some people are alive only because
 Click to see the full signature
Reply to
Bob Larter

If the 'phone rings while you are doing the ironing, you can get a badly burned ear.

--
~ Adrian Tuddenham ~
(Remove the ".invalid"s and add ".co.uk" to reply)
 Click to see the full signature
Reply to
Adrian Tuddenham

Two deathly dangers - one from actual electrical shock, one from impaling yourself on something sharp when you jump from the shock and bleed to death

A good reason to find another line of work. Just remember, a live circuit looks exactly like a dead circuit. Also HV caps can hold a charge enough to bang you too. If you learned on tube gear, then maybe you know enough, but LV circuits just don't have the urgency required to heighten your paranoia for survivability. You essentially have to develop a checklist in your head for each time you put a hand (only one) into the dead equipment and never fail. Instructions are normally in the Service Manual of all HV equipment.

Reply to
JB

My classic screwup was a time, as a smartarse teenager, when I was working on a 28" display monitor, & /thought/ I'd discharged the CRT correctly via the ultor cap. I lifted the ultor cap to unhook it, & a giant spark bit me. The shock threw me clear across the room, & I just missed slamming into a bench.

All good advice.

--
    W
  . | ,. w ,   "Some people are alive only because
 Click to see the full signature
Reply to
Bob Larter

This explains a lot! ;-)

--
You can\'t have a sense of humor, if you have no sense!
Reply to
Michael A. Terrell

I suppose you've never zapped yourself? ;^)

--
    W
  . | ,. w ,   "Some people are alive only because
 Click to see the full signature
Reply to
Bob Larter

Not like that. The HV I worked with wasn't measured in micro amps. It was inside the TV transmitter. One touch, and you're dead. Think what a HV DC power supply for three 65 KW Klystrons would do to you, when the power supply put out a continuous 195 KW. In fact, you wouldn't even need to touch it.

--
You can\'t have a sense of humor, if you have no sense!
Reply to
Michael A. Terrell

Scares the crap out of me just thinking about it! I've only ever worked consumer electronics, never had any training on high voltage / high frequency power circuits.

I once got shocked by a GE 35" tv by only getting near the anode wire. The wire had cracks in it, and I didn't know until it was too late. Felt like it took my arm off!

More than once grazed some skin across 120 volts AC whilst working on equipment; never got much more than a "Huh? What was that? Oh, crap. Gotta be more careful..."

Mark Z.

Reply to
Mark Zacharias

Funny thing is that 120 volts AC is actually more likely to kill you than 240 volts!

Reply to
PeterD

That is why there are so many safety interlocks in big transmitters. I was moving a RCA TTU-25B transmitter about 15 years ago, and found a small screwdriver jammed in one of the interlock switches. Luckily, the highest voltage in that cabinet was around 350 volts DC, but several of the other cabinets had 7000 VDC for the two water cooled power tetrodes. The transmitter was in nine, four foot square aluminum cabinets that were about seven feet tall. There were two, two foot wide sections that held the special rubber pipe that isolated the HV from ground. That made the entire transmitter 4 feet deep, 40 feet wide and seven feet tall.

--
You can\'t have a sense of humor, if you have no sense!
Reply to
Michael A. Terrell

Gotta

Only because you may be exposed to it a lot more often. Consider that at

240v you will be dissipating 4 times the power through your bod!
Reply to
JB

Oh, you should try working the CO frame in Palm Desert! Temperature is about 90, even with the HVAC running full out, and you put your arm across a set of pins just as ring voltage comes through.

ZAP! your arm jerks up...

OUCH! as you impale your arm on the pins above

ZAP! as your arm comes back down on the pins below just as another ring hits...

OUCH!!!! as you impale your arm on the pins above again!

Usually, after about two hits you get control... ;-)

Charlie

Reply to
Charlie E.

Mine was moving the meter probe tips slightly while looking over at the meter. Diodes explode into many fast moving pieces, and melt your probe tips. Wear a full face shield, not just goggles, and a heavy duty full sleeve lab coat. Remove watches, rings, necklaces, etc. If you don't want a spark to hit it, don't put metal on it.

Reply to
Wes

On 5/8/2009 3:06 PM Charlie E. spake thus:

Hah! That reminds me of that ditty about the Irishman hoisting bricks up with a pulley ...

... ah, there it is:

Why Paddy's Not At Work Today (Tune: "In The Garden Where The Praties Grow")

Dear Sir, I write this note to you to tell you of my plight For at the time of writing I am not a pretty sight My body is all black and blue, my face a deathly grey And I write this note to say why Paddy's not at work today.

Whilst working on the 14th floor some bricks I had to clear To throw them down from such a height was not a good idear The foreman wasn't very pleased, the bloody awkward sod And he said I'd have to cart them down the ladders in me hod.

Now clearing all these bricks by hand, it was so very slow So I hoisted up a barrel and secured the rope below But in my haste to do the job I was too blind to see that a barrel full of building bricks was heavier than me!

And so when I untied the rope, the barrel fell like lead And, clinging tightly to the rope, I started up instead I shot up like a rocket til to my dismay I found That halfway up I met the bloody barrel coming down!

The barrel broke my shoulder, as toward the ground it sped And when I reached the top, I banged the pulley with my head I hung on tightly, numb with shock, from this almighty blow And the barrel spilled out half the bricks, 14 floors below.

Now when these bricks had fallen from the barrel to the floor I then outweighed the barrel, and so started down once more Still clinging tightly to the rope, my body racked with pain When, halfway down, I met the bloody barrel once again!

The force of this collision, halfway up the office block caused multiple abrasions and a nasty state of shock Still clinging tightly to the rope, I fell towards the ground And landed on the broken bricks the barrel scattered round!

I lay there, groaning, on the ground; I thought I'd passed the worst But the barrel hit the pulley wheel, and then the bottom burst... A shower of bricks rained down on me; I hadn't got a hope... As I lay there bleeding on the ground, I let go the bloody rope!

The barrel it was free to fall, and down it came once more And landed right across me, as I lay upon the floor It broke three ribs and my left arm, and I can only say: That I hope you understand why Paddy's not at work today!

--
Save the Planet
Kill Yourself
 Click to see the full signature
Reply to
David Nebenzahl

"JB" wrote in news:C31Nl.69$5F2.54 @nwrddc01.gnilink.net:

No! Because 240 is more likely to 'throw you off' and 120 is more likely to 'freeze you on'.

15 micro amps across the heart kills. 60 Hz is especially bad for causing V-fib. Without a defibrillator, or CPR you are dead in 6 minutes. 15 milli amps is sufficient to 'freeze your muscles' so you can't let go. You start with relatively dry skin and get a good grip onto a hot item. You can't let go. Skin at the points of contact blisters. resistance goes down. current goes up. you cook.

Higher voltages produce very violent muscle contractions and can (if you are lucky) throw you clear of the circuit.

--
bz    	73 de N5BZ k

please pardon my infinite ignorance, the set-of-things-I-do-not-know is an 
 Click to see the full signature
Reply to
bz

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.