Hi, Hope this is the right news group for this questions...
Does anyone have details of the strike voltage and running requirements for
90W SOX lamps? ThanksHi, Hope this is the right news group for this questions...
Does anyone have details of the strike voltage and running requirements for
90W SOX lamps? Thanks
Xpost and f'up2 sci.engr.lighting
There is an ANSI standard C78.41-2001:
There you can get the following data for the 90 W SOX lamp:
- minimum open circuit voltage: 420 V rms - nominal operating voltage: 112 V rms - nominal operating current: 0.94 A rms - nominal operating wattage: 91 W - maximum crest factor: 1.6
Christian.