Xilinx EDK: XPS netlist combination error

030506060901040504070007 Content-Type: text/plain; charset=ISO-8859-1; format=flowed Content-Transfer-Encoding: 7bit

Hello all,

Does anyone know why I keep getting errors like this:

" ERROR:EDK:708 - Can not get list of netlist files for core xps_fb_img_xform 1.01.a . The pcore has a pre-synthesized netlist specified through BBD and the list of parameter combinations listed for the instance in MHS does not match any of the combinations in the BBD. "

I've enclosed a file showign how the core entry looks like in the MHS file, as well as the cores BBD file contents.

Could it be something with directory paths and/or spaces or whatever. There are no tab characters in the BBD file.

It's quite annoying.

Thanks all,

Finn S. Nielsen Morphologic ApS

formatting link

Reply to
Finn S. Nielsen
Loading thread data ...

If no-one here answers you, try a at:

formatting link

--------------------------------------- Posted through

formatting link

Reply to
RCIngham

Den 05-10-2011 16:09, Finn S. Nielsen skrev:

OK All, here's an explanation:

XPS will read the default parameter values and try and match these settings with the combinations in the BBD file. If it doesn't find it it issues an error message. This does however have nothing to do with the parameters in the MHS file which it will only check during system build... So the default parameter combination must exist to avoid the error message - which should not really be an error, but rather a warning instead.. ( add that to the gazillion other warnings... ;-) )

Happy hacking,

Finn S. Nielsen Morphologic ApS

formatting link

Reply to
Finn S. Nielsen

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.