simple question... IMPACT doesn't recognize my xilinx parallel cable IV when downloading projects to the board. I have read in some articles that a power supply is necessary to power up the cable, but there is no power supply or adapter in the box where the
cable came.
------Can any one tell me what do i do? as my laptop does not have the socket for the pin that is with parallel cable IV... which i think may be for powering up the cable
-----and it also says Checking cable driver. File C:\WINDOWS\system32\drivers\xusbdfwu.sys not found. There was no driver cd withthe virtex -II pro xc2vp7 board...where do i get this xusbdfwu.sys file...
Thanks in advance from this starter. attached is the error i get when i am trying to connect the cable to download the stream to board. Regards
--------------------------------------------------------------------------------------------------------
INFO:iMPACT:1777 - Reading C:/Xilinx/virtex2p/data/xc2vp70.bsd... INFO:iMPACT:1777 - Reading C:/Xilinx/virtex2p/data/xc2vp70.bsd... INFO:iMPACT:501 - '1': Added Device XC2VP70 successfully.
----------------------------------------------------------------------
----------------------------------------------------------------------
----------------------------------------------------------------------
---------------------------------------------------------------------- INFO:iMPACT:1777 - Reading C:/Xilinx/virtex2p/data/xc2vp70.bsd...
---------------------------------------------------------------------- // *** BATCH CMD : setAttribute -position 1 -attr devicePartName -value "xc2vp70" // *** BATCH CMD : setAttribute -position 1 -attr configFileName -value "C:\Xilinx\virtex2p\data\xc2vp70.bsd" INFO:iMPACT:501 - '1': Added Device XC2VP70 successfully.
----------------------------------------------------------------------
----------------------------------------------------------------------
----------------------------------------------------------------------
---------------------------------------------------------------------- INFO:iMPACT:1777 - Reading C:/Xilinx/virtex2p/data/xc2vp70.bsd... GUI --- Add one device. GUI --- #1 xc2vp70 C:\Xilinx\virtex2p\data\xc2vp70.bsd Device #1 selected Device #1 selected GUI --- Auto connect to cable... // *** BATCH CMD : setCable -port auto AutoDetecting cable. Please wait. CB_PROGRESS_START - Starting Operation. Connecting to cable (USB Port). Cable connection failed. Connecting to cable (Parallel Port - LPT1). Checking cable driver. Driver windrvr6.sys version = 6.2.2.2. LPT base address = 0378h. ECP base address = 0778h. Cable connection failed. Connecting to cable (Parallel Port - LPT2). Checking cable driver. Driver windrvr6.sys version = 6.2.2.2.Cable connection failed. Connecting to cable (Parallel Port - LPT3). Checking cable driver. Driver windrvr6.sys version = 6.2.2.2.Cable connection failed. Connecting to cable (Parallel Port - LPT4). Checking cable driver. Driver windrvr6.sys version = 6.2.2.2.Cable connection failed. Connecting to cable (Usb Port - USB21). Checking cable driver. File C:\WINDOWS\system32\drivers\xusbdfwu.sys not found. Driver file not found. Inf file version = 0. Driver xusbdfwu.sys version: 1017 (1017). Driver windrvr6.sys version = 6.2.2.2.Cable connection failed. Connecting to cable (COM1 Port). Cable connection failed. Cable connection failed. Cable connection failed. Cable connection failed. CB_PROGRESS_END - End Operation. Elapsed time = 29 sec. Cable autodetection failed. WARNING:iMPACT:923 - Can not find cable, check cable setup !