No results show up after "dow" and "con" in hypertrm

Hi, all

I am a student in Beihang University in Beijing, P.R.China. I just started to learn to build a system uClinux on Microblaze. I m reading a document named uClinux_ready_Microblaze_design_1_05_a.

I met a problem. My target board is just ML401, using EDK 8.1 as told in the doc. I strictly followed the steps and everything seems going smoothly, until the last step of downloading kernel image to the target board. Still there are no errors both in the XMD command line and board. There is no uClinux bootup infos in hypertrm either. I wonder whether there is any error with the kernel image or there are any other errors.

Maybe some of the questions are silly. Thanks very much for your patient of reading through my e-mail. Hope u can help me.

Orlando Sun

The following is the output from the XMD.

##################### XMD% bash dl.sh Memory address Found Memory Address is 0x24000000 Device xc4vlx25 Found Architecture device is xc4vlx25 Kimage is image.bin Kparams are Xilinx Microprocessor Debug (XMD) Engine Xilinx EDK 8.1.02 Build EDK_I.20.4 Copyright (c) 1995-2005 Xilinx, Inc. All rights reserved.

XMD% XMD% Loading MHS File.. Processor(s) in System ::

Microblaze(1) : microblaze_0 Address Map for Processor microblaze_0 (0x00000000-0x00001fff) dlmb_cntlr dlmb (0x00000000-0x00001fff) ilmb_cntlr ilmb (0x22000000-0x227fffff) FLASH_2Mx32 mb_opb (0x24000000-0x27ffffff) DDR_SDRAM_64Mx32 mb_opb (0x40600000-0x4060ffff) RS232_Uart mb_opb (0x41200000-0x4120ffff) opb_intc_0 mb_opb (0x41400000-0x4140ffff) debug_module mb_opb (0x41c00000-0x41c0ffff) opb_timer_1 mb_opb

XMD% No such Gdb Server

No Processor target with id = 0 XMD% XMD% Connecting to cable (Parallel Port - LPT1). Checking cable driver. Driver windrvr6.sys version = 7.0.0.0. LPT base address = 0378h. ECP base address = 0778h. Cable connection failed. Connecting to cable (Parallel Port - LPT1). Checking cable driver. Driver windrvr6.sys version = 7.0.0.0. LPT base address = 0378h. ECP base address = 0778h. Cable connection failed. Connecting to cable (Parallel Port - LPT2). Checking cable driver. Driver windrvr6.sys version = 7.0.0.0.Cable connection failed. Connecting to cable (Parallel Port - LPT2). Checking cable driver. Driver windrvr6.sys version = 7.0.0.0.Cable connection failed. Connecting to cable (Usb Port - USB22). Checking cable driver. Driver xusbdfwu.sys version: 1018 (1018). Driver windrvr6.sys version = 7.0.0.0.Calling setinterface num=0, alternate=0. DeviceAttach: received and accepted attach for: vendor id 0x3fd, product id 0x8, device handle 0x2970038 Max current requested during enumeration is 280 mA. Cable Type = 3, Revision = 0. Setting cable speed to 6 MHz. Cable connection established. Firmware version = 1018. CPLD file version = 0006h. CPLD version = 0012h.

JTAG chain configuration

-------------------------------------------------- Device ID Code IR Length Part Name 1 0a001093 8 System_ACE 2 05059093 16 XCF32P 3 0167c093 10 XC4VLX25 4 09608093 8 xc95144xl Assuming, Device No: 3 contains the MicroBlaze system Connected to the JTAG MicroProcessor Debug Module (MDM) No of processors = 1

MicroBlaze Processor 1 Configuration :

------------------------------------- Version............................4.00.a No of PC Breakpoints...............2 No of Read Addr/Data Watchpoints...0 No of Write Addr/Data Watchpoints..0 Instruction Cache Support..........on Instruction Cache Base Address.....0x24000000 Instruction Cache High Address.....0x27ffffff Data Cache Support.................on Data Cache Base Address............0x24000000 Data Cache High Address............0x27ffffff Exceptions Support................off FPU Support.......................off FSL DCache Support.................off FSL ICache Support.................off Hard Divider Support...............off Hard Multiplier Support............on Barrel Shifter Support.............off MSR clr/set Instruction Support....off Compare Instruction Support........off JTAG MDM Connected to MicroBlaze 1 Connected to "mb" target. id = 0 Starting GDB server for "mb" target (id = 0) at TCP port no 1234 XMD% Downloading kernel image... XMD% This will only take a few seconds! XMD% XMD% setting kernel command line XMD% XMD% "cmdline is " XMD% 2 XMD% 0x100 XMD% > > > > XMD% XMD% XMD% XMD% Processor started. Type "stop" to stop processo r RUNNING> Done already WOW! RUNNING> Closing MDM communication with Processor 1 ##############################