Chipscope and Virtex4 LX25 ES

Hi,

Xilinx solution 20060 refers to the issue with the Virtex 4 LX25 ES parts and the JTAG chains, with workarounds for the EDK's XMD and opb_mdm tools. However, this silicon bug also affects ChipScope Pro, but no solution is offered.

We are considering prototyping a large project on the ML401 (which uses V4-LX25 ES parts), but ChipScope support will be essential. Does anybody have some good news for me that there is, or soon will be, a workaround for this?

Thanks,

John

Reply to
John Williams
Loading thread data ...

ChipScope works actually with LX25-ES but you can not use MDM and Chipscope in the same design thats the limitation also on our board (memec LX25) Chipscope is not able to download the bitstream so the bitstream has to be loaded with impact, later chipscope would be useable

Antti PS I think there will be no complete workaround to get USER2 to work on ES there was report that USER2 has reset polarity inverted? that is not completly dead, so I assume the silicon might allow for a fix, but my strong bet is that the USER2 fix for chipscope-mdm will not be offered by Xilinx

"John Williams" schrieb im Newsbeitrag news:newscache$d8lsdi$pbh$ snipped-for-privacy@lbox.itee.uq.edu.au...

Reply to
Antti Lukats

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.