Problem in getting Colilo Prompt (mcf5485)

Hi,

I have downloaded the srec file through network using TeraTerm in windows 2000 SP4. the first time I downloeded the code, I got the colilo prompt and it was working just fine. now when I reset the board and trying to run the same steps again it displays the garbage data. the following is copy of tera-term output.

ColdFire MCF548X on the M5485EVB Firmware v3b.1a.1b (Built on Sep 1 2004 16:40:20) Copyright 1995-2004 Freescale Semiconductor, Inc.

Enter 'help' for help.

dBUG> show base: 16 baud: 115200 server: 10.0.0.77 client: 10.0.0.80 gateway: 10.0.0.1 netmask: 255.0.0.0 filename: colilo_mcf5485.srec filetype: S-Record ethaddr: 00:CF:54:85:CF:01 dBUG> dn Downloading S-Record 'colilo_mcf5485.srec' from 10.0.0.77 S-record download successful! TFTP transfer completed Read 196796 bytes (385 blocks) dBUG> go 0x1000400 =E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0= =E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0= =E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0

regards

Fakhar

Reply to
bazooka
Loading thread data ...

by default colilo operates on 19200 baud rate

set baud 19200

go 0x1000400

FireEngine board boot... Colilo>