PIC24HJ64GP206, ICD2 -> ICD0083: Debug: Unable to enter debug mode.

Do you have a question? Post it now! No Registration Necessary

Translate This Thread From English to

Threaded View
Hi

I hoping some one might be able to point me in the right direction.

I am using a PIC24HJ64GP206 with an ICD2 connected to PGD2 and PGC2.
When I tell the ICD2 to connect to the target it does so without
error, identifies the chip etc.... see below;

Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to target
Target Device PIC24HJ64GP206 found, revision = Rev 0x3002
...Reading ICD Product ID
Running ICD Self Test
...Passed
MPLAB ICD 2 Ready

However, if I build my code and tell it to program the chip i get
ICD0083: Debug:  Unable to enter debug mode.  Please double click this
message for more information    See below.

Programming Target...
...Validating configuration fields
...Erasing Part
...Programming Program Memory (0x0 - 0x4FF)
Verifying...
...Program Memory
...Verify Succeeded
...Loading DebugExecutive
...Programming DebugExecutive
...Debug Executive
...Programming Debug Vector
...Debug Vector
...Programming Configuration Bits
.. Config Memory
Verifying configuration memory...
Connecting to debug executive
ICD0083: Debug:  Unable to enter debug mode.  Please double click this
message for more information.
MPLAB ICD 2 Ready

Does anyone have any ideas as to what I can/should check ?

I have used the C18 compiler with the PIC18F series devices but this
is my 1st application using c30 on a PIC24.

All helpful comments,things to check etc.... welcome.

Thanks in advance

Anbeyon


Re: PIC24HJ64GP206, ICD2 -> ICD0083: Debug: Unable to enter debug mode.
On 25 May 2007 07:27:36 -0700, the renowned Anbeyon

Quoted text here. Click to load it

http://forum.microchip.com/tm.aspx?m14%1274


Best regards,
Spehro Pefhany
--
"it's the network..."                          "The Journey is the reward"
snipped-for-privacy@interlog.com             Info for manufacturers: http://www.trexon.com
We've slightly trimmed the long signature. Click to see the full one.
Re: PIC24HJ64GP206, ICD2 -> ICD0083: Debug: Unable to enter debug mode.
Quoted text here. Click to load it

Thanks - It was cable length related - all seems OK now :0)