PDIUSBD12,non sense interrupt 0xC3?

Hello, i builded at a board based on a PDIUSB12 USB controller and

9s12e64 uC (i choose the Hc12 uC is because i can debug it pretty easil with the BDM interface) I used as a trace the code fro
formatting link
that was intended for PDIUSBD11. I think that my board is electrically ok:the D12 responds correctly t commands as Set_Clk_Out,Soft connect and so on..

The problem is that during enumeration i read from the D12 an Irq value o

0x03 or 0x83, the low nibble=3 indicates that the bits indicating CTRL_I interrupt and CTRL-OUT interrupt are both set,and this sounds like a no sense,the host can't require a byte and in the same time have a byte t send.The two pins D0 and D1 are not shorted,i verified they can hav different levels Thank you for any help,or just for read this Diego Milano
Reply to
diegotrex
Loading thread data ...