PCI BAR0 with 8349

Hi,

I am facing a problem..Any one find this kind of situation?

I had connected a PCI device with MPC8349.

POBAR1 = 0x90000000 POTAR1 = 0x50000000 POCMR1 =0xA00fc000 (64 MB)

after running the auto configuration the BAR0 0f the pci device get

0x90100000 According my understanding it should be like 0x50100000 like that.as the the BAR0 of PCI device is holding the PCI address space instead of address of local bus in MPC side.

NB: When configured with the values. POBAR1 = 0x90000000 POTAR1 = 0x90000000 POCMR1 =0xA00fc000

The device is working properly.Then also BAR0 = 0x90100000 which correct I guess.

Anyone can please explain?

I posted the same topic in vxworks forum for better no of feedbacks. Regards, Nabendu