18bit lvds to 8bit lvds lcd

hi guys do any one knows how to convert or connect a kino 945gse motherboard lvds output (30 pin 18 bit 25mhz) to a AUO lcd monitor t315xw03(The T315XW03 V3 has been designed to apply the 8-bit 1 channel LVDS interface method. It is intended to support displays where high brightness, wide viewing angle, high color saturation, and high color depth are very important.)

if anyone can assit i would appreciate it. Nico

LCD Pin No P-two 196282-30041

1 Reserved No Connect ( AUO Internal Use) 2 Reserved No Connect ( AUO Internal Use) 3 Reserved No Connect ( AUO Internal Use) 4 GND Ground 5 R_0- LVDS Channel, Signal 0- 6 R_0+ LVDS Channel, Signal 0+ 7 GND Ground 8 R_1- LVDS Channel, Signal 1- 9 R_1+ LVDS Channel, Signal 1+ 10 GND Ground 11 R_2- LVDS Channel, Signal 2- 12 R_2+ LVDS Channel, Signal 2+ 13 GND Ground 14 R_CLK- LVDS Channel, Clock - 15 R_CLK+ LVDS Channel, Clock + 16 GND Ground 17 R_3- LVDS Channel, Signal 3- 18 R_3+ LVDS Channel, Signal 3+ 19 GND Ground 20 Reserved No connect ( AUO Internal Use) 21 LVDS_SEL Open/High(3.3V) for NS, Low(GND) for JEIDA 22 Reserved No Connect ( AUO Internal Use) 23 GND Ground 24 GND Ground 25 GND Ground 26 VDD Operating Voltage Supply, +12V DC Regulated 27 VDD Operating Voltage Supply, +12V DC Regulated 28 VDD Operating Voltage Supply, +12V DC Regulated 29 VDD Operating Voltage Supply, +12V DC Regulated 30 VDD Operating Voltage Supply, +12V DC Regulated

kino bord Pin No P-two 196282-30041

1 Reserved No Connect ( AUO Internal Use) 2 Reserved No Connect ( AUO Internal Use) 3 Reserved No Connect ( AUO Internal Use) 4 GND Ground 5 R_0- LVDS Channel, Signal 0- 6 R_0+ LVDS Channel, Signal 0+ 7 GND Ground 8 R_1- LVDS Channel, Signal 1- 9 R_1+ LVDS Channel, Signal 1+ 10 GND Ground 11 R_2- LVDS Channel, Signal 2- 12 R_2+ LVDS Channel, Signal 2+ 13 GND Ground 14 R_CLK- LVDS Channel, Clock - 15 R_CLK+ LVDS Channel, Clock + 16 GND Ground 17 R_3- LVDS Channel, Signal 3- 18 R_3+ LVDS Channel, Signal 3+ 19 GND Ground 20 Reserved No connect ( AUO Internal Use) 21 LVDS_SEL Open/High(3.3V) for NS, Low(GND) for JEIDA 22 Reserved No Connect ( AUO Internal Use) 23 GND Ground 24 GND Ground 25 GND Ground 26 VDD Operating Voltage Supply, +12V DC Regulated 27 VDD Operating Voltage Supply, +12V DC Regulated 28 VDD Operating Voltage Supply, +12V DC Regulated 29 VDD Operating Voltage Supply, +12V DC Regulated 30 VDD Operating Voltage Supply, +12V DC Regulated

--------------------------------------- Posted through

formatting link

Reply to
asbestikum
Loading thread data ...

ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.