Måle/logge temperatur via PC - hvordan?

Hvordan kommer jeg lettest (billigst) i gang med at måle og gerne logge temperaturer via PC'en. Enten via USB, seriel- eller parallelporten.

- Temperaturintervallet er ca. 20-100 grader celcius.

- Præcisionen er ikke altafgørende, da jeg har et termometer jeg kan "kalibrere" med

- Skal bare vise "nøjagtigt" indenfor ca. 1-2 grader. Altså hvis jeg f.eks, ved at 250 ohm er lig med 45 grader skal det også gerne ramme tæt på 250 ohm næste gang temperaturen er 45 grader.

- Selve logningen må genre kunne omregne fra ohm til grader elelr mA til grader altså så selve formlen beregnes kontinuerligt.

Nogle forslag?

--
-Fly
doktor_flyMONKEY@hotmail.com
(Please remove the animal from my e-mail)
Reply to
Fly
Loading thread data ...

Fly skriver:

formatting link

Klaus

-- Modelbane Europas hjemmeside:

formatting link
Modeltog, internet, gratis spambekæmpelse, elektronik og andet:
formatting link

Reply to
Klaus D. Mikkelsen

Har Du nogen erfaringer med om det virker på en PC af den slags man bruger nu om dage?

Siden windows 2000 har det ikke været muligt at skrive/læse direkte fra porte i en PC, men mindre man har en kerne-driver, der kan formidle det.

Har Du evt kendskab til om der findes en let tilgængelig (og betalelig) driver, der muliggør at komme i kontakt med f.x. printerporten under W/2k og W/XP ?

Bo //

Reply to
Bo Bjerre

Jeg mener at jeg benyttede denne sidste gang jeg skulle:

formatting link

Med venlig hilsen Preben

Reply to
Preben Bohn

Prøv at kigge her

formatting link

En færdig programmeret pic der kan tale med dallas's onewire temperatur sensorer og levere resultatet serielt.

Jeg købte et byggesæt for snart 5år år siden - Det er ihvertfald nemt :-)

Reply to
Anders Majland

Fly skrev:

ge=20

n=20

g f.eks,=20

=E5 250 ohm=20

til=20

maxim/atmel har en integret kres som de levere program til den taler=20 serielt elektor har ogs=E5 og der et firma som har en 4benet kres med tem= p=20 og fugtighedsm=E5ler mvh

Reply to
bamse

Bo Bjerre skriver:

Ikke direkte

port95.exe følger med eksempelvis JaLCD, den bliver til "DriverLINX Port I/O".

Klaus

--
  Modelbane Europas hjemmeside: http://www.modelbaneeuropa.hadsten.dk
  Modeltog, internet, gratis spambekæmpelse, elektronik og andet:
                 http://home6.inet.tele.dk/moppe
Reply to
Klaus D. Mikkelsen

Hej igen!

Måske har jeg rodet mig ud i noget der er lidt mere langhåret end jeg regnede med.

Er der nogle af jer der har erfaringer med denne slags temperaturmåling OG har de rette programstumper liggende. Det eneste jeg har brug for er at logge temperatur og tidspunkt med f.eks. 5 sekunders interval eller måske endda kun en gang i minuttet.

Denne log kan enten være i et stykke windows-software eller som en rå kommasepareret tekstfil (eller lignende)

Jeg kan sagten selv lodde tingene sammen og skaffe stumperne, men har ikke lige styr på parallelporten eller serielporten så langt nede i signaleringen :-D

-Fly

Reply to
Fly

Hvis du ikke gider bygge selv, så kan du købe sådan noget her:

formatting link
?lang=dk&vat=0&dok=6837.htm

Reply to
HKJ

-kigger jeg nærmere på, takker

Bo //

Reply to
Bo Bjerre

Jeg troede det var nabo til umuligt :-)

Bo //

Reply to
Bo Bjerre

Bo Bjerre skriver:

Lad mig sige det sådan: Med JaLCD virker det fint.

Klaus

-- Modelbane Europas hjemmeside:

formatting link
Modeltog, internet, gratis spambekæmpelse, elektronik og andet:
formatting link

Reply to
Klaus D. Mikkelsen

Hvad med noget i retning af denne:

formatting link

--
  Med venlig hilsen,    Ove Kjeldgaard,    nospam AT privat DOT dk
  Natur og Friluftsliv:
Reply to
Ove Kjeldgaard

"Fly" skrev i en meddelelse news:45c7b8a2$0$156$ snipped-for-privacy@dread11.news.tele.dk...

temperaturer via PC'en. Enten via USB, seriel- eller

Mit multimeter har det som standart til kr. 765,- inkl. temp sersor og logger software, der logger alt det instrumentet kan måle.

[
formatting link
]

Billede af logger software.

formatting link

Den kan også logge til en tekst fil , eks.

1 TE 0024 C 16:58:16 2 TE 0024 C 16:58:17 3 TE 0024 C 16:58:18 4 TE 0024 C 16:58:19 5 TE 0024 C 16:58:20

Jan Rasmussen

Reply to
Jan Rasmussen

-------------------------------------------------------

Hej Jan!

Det lyder meget tiltalende med et multimeter der kan tilsluttes en PC'er.

Jeg har kigget på diverse specifikationer på nettet over netop den model du anbefaler, men jeg kan ike finde svaret på en enkelt ting, så jeg håber at du kan svare på det:

Kan multimeteret logge uden det er tilkoblet en PC - altså er der en antal "liniers" hukommelse i det og evt. hvor meget? Jeg kunne til nogle af målingerne godt have brug for at logge uden PC er tilsluttet, selvom det er et luxusproblem :-)

--
-Fly
doktor_flyMONKEY@hotmail.com
(Please remove the animal from my e-mail)
Reply to
Fly

"Fly" skrev i en meddelelse news:45cb0a59$0$227$ snipped-for-privacy@dread11.news.tele.dk...

Det kan den ikke. Hvis du kikker efter bliver den heller ikke solgt som et instrument med datalogger, men som et instrument med RS232 interface. Det er PC-programmet, og PCén hukommelse, der gør det muligt at anvende instrumentet som datalogger. Det er stadig en smart feature, som det ikke koster ret meget at tilbyde.

Reply to
Allan Soerensen

"Allan Soerensen" skrev i en meddelelse news:45cb1459$0$859$ snipped-for-privacy@dread12.news.tele.dk...

news:45cb0a59$0$227$ snipped-for-privacy@dread11.news.tele.dk...

"liniers" hukommelse i det og evt. hvor meget?

tilsluttet, selvom det er et luxusproblem :-)

datalogger, men som et instrument med RS232 interface.

instrumentet som datalogger. Det er stadig en smart

Korekt.

Mit indtryk er at, instrumenten blot smider måle data ud på RS232 interfacet vært sekund, og man kan så vælge at programmet skal opsamle med en lavere hastighed, fra 1 til 5000 sekunder.

Programmet er lidt windows95/98 agtigt, men virker på XP

Nedestående er fra programmets help - readme

Jan Rasmussen

MAS_View Version 1.1 Copyright 2000

Welcome: MAS_View Software is designed to receive, record and graphically present Digital Multimeter (DMM) measurement data. Please read this file to assist you in understanding MAS_View features, getting MAS_View software properly configured, and learning some helpful tips.

Compatibility: Hardware Requirements: PC 486 or better Operating System: Microsoft Windows Version 95 (minimum) Digital Multimeter (DMM) compatibility: MAS340 Series

Installation: MAS_View requires at least 2 megabytes of space for installation. Install MAS_View through standard Window's installation procedure: Boot up your computer on Windows and insert the MAS_View diskette into disk drive A or B. From the Windows Program Manager select 'Run' from the File Menu. For MAS_View in disk A type:a:\setup and press the 'Enter' key. For MAS_View in disk B type:b:\setup and press the 'Enter' key. It'll install the program as you select folder name.

Set up: Connect the Multimeter to your computer's COM Port (Reference your computer hardware manual if necessary). Make note of which port (COM1 to COM2) the meter has been connected. And select COM1 or COM2. Turn on Meter. Run MAS_View program.

COM Port - Select the port that the meter is connected to.

Operation: Make sure the meter is properly attached to the computer, the meter is ON and the meter display is active. Run the MAS_View program. Click on MAS_View's Communication ONline command key. The reading on the meter should now be the same as on the computer display. If the software fails to display a reading, recheck the meter's connections to the computer. Also check the COM PORT settings are correct. MAS_View functions are run by clicking on the Program's Command Keys and Icons. Check boxes, option buttons, and data fields will customize how data can be gathered.

DMM Setting: Set the DMM to the proper measurement and meter range before the 'On-Line' button is pressed. Changing the DMM setting in the middle of a Graph Window mode run may cause a data interruption, a reset of the sweep in progress, or mis-scaled data readings.

Help: On screen HELP information is provided throughout MAS_View.

CAPTURE Buzzer Comparators The Window Comparators are a flexible data filtering tool. The High Limit and Low Limit may be set to work individually or together for Buzzer function.

Window Scale It zooms each of 4 basic window modes;Value window, Gauge window, Graph window and Data window.

Value Window Mode: Displays read time data.

Graph Window Mode: In the data display window, collected data is graphically displayed, a real-time meter is shown, scope range is shown. It can be printed with the printer connected to computer.

Sampling Time: Minimum Sampling Time of Meter Data: 1 sample/second. In auto mode, it is fixted to the 1 sample/second. In manual mode, you can set the sampling time in second.

Gauge Window Mode: In guage mode, the screen displays the percentage of current measurement value of the range.

Data Window Mode: accumulates the meauring values with time in the file specified. The list can be printed with the printer connected to the computer.

--- MENU ---

File Printer : Setup Printer Print -Graph : Print Graph -Data Sheet : Print Data Sheet Communication On Line : On Line with DMM Off Line : Off Line with DMM Port : Select Port (COM1,COM2) Buzzer Buzzer off : Always Buzzer turns off. Low > : Buzzer beeps when the input value is smaller than Low setting value. Hi < : Buzzer beeps when the input value is bigger than High setting value. Low < and < Hi : Buzzer beeps when the input value is between Low setting value and High setting value. Low > or > Hi : Buzzer beeps when the input value is smaller than Low setting value or bigger than High setting value. Window Scale Value window : Enlarge Funtion & Data display section. Gauge window : Enlarge Gauge display section. Graph window : Enlarge Graph display section. Data window : Enlarge Data Sheet display section. Help Readme : Display Readme.txt file About : Display Mas-view Logo and Version.

--- SETTING in the Display ---

File name : For starting to record and Graph input values by new file, input the new file name in the center of the upper status bar. Auto Select : Communication interval is set to 1 sec in Auto setting. Manual Select : Communication interval is set to the seconds of the input number. Buzzer Low : Low value setting for buzzer beep condition. Buzzer Hi : High value setting for buzzer beep condition. X Grid,Y Grid Select : Set X or Y Grid on the Graph display. Back Ground,Line Select : Set the color of back ground & Line on the Graph display. Auto Graph : Vertical reference value on the Graph display is adjusted automatically by the input value. Vert offset, Vert Max : Set the vertical reference value on the Graph display when the Auto Graph is not selected.

--- Zoom on The Graph Display ---

On the Graph display, from the point selected by pressing left key of the Mouse to the right-down dragging point by the Mouse, the selected area is zoomed in(enlargement). To return back to the previous display,drag the Mouse left-up ward during the left key on the Mouse pressed.

--- ICONS ---

Exit Program : Exit from this software. Data Clear : Clear all data and ready for start with the same file name. Printer Setup : Set up a Printer. On Line : On Line and communicate with the DMM Off Line : Off Line and stop to communicate with the DMM

NOTE In the automatical graph mode, reference grid and Y axis value are reset according to the current function and range data from the meter connected to the P/C. Display keeps graphing by new input value with the previous graph. So, when rotary switch is turned to a different position, data clear function had better be performed in advance for avoiding mis-scaled graph. Range hold on the meter is recommendable for a safe graphing.

Reply to
Jan Rasmussen

Der er også det her til 399,- + moms:

formatting link

eller USB:

formatting link

Jeg har ikke megen erfaring med Danbit; de skriver at de ikke sælger til private, men det er der så mange der skriver og alligevel gør de det når man står der og vifter med 100 kr sedler.

--
hilsen Ole
(mail: fjern x'erne i mail adr.)
Reply to
Ole Pagh

"Fly" skrev i en meddelelse news:45c7b8a2$0$156$ snipped-for-privacy@dread11.news.tele.dk...

Hej

Hvad med at bestille lidt gratis samples hos dalsemi.com - jeg har selv fået tilsendt diverse I-buttons samt et USB interface u/b Hvis ikke du ved hvad I-buttons er, så ligner de et knapcelle batteri og kan indeholde f.eks. en temperaturlogger som du søger. Du kan sætte den op til at starte på et givet tidspunkt, hvor tit der skal samples og meget mere. Jeg har selv lige haft en sat på min centralvarme (med et par elastikker) for at se om natsænkningen virkede - lod den køre i en uges tid, og fik udlæst data på pc'en med graf over temperaturen ;)

Jens

Reply to
Jens Jespersen

"Jens Jespersen" skrev i en meddelelse news:45cc5965$0$48091$ snipped-for-privacy@dread16.news.tele.dk...

Selve USB-sticken med 1-wire interface kan man ikke få som sample mere (Dallas har tilmed et lille gratis datalogger-program, der kan bruges sammen med deres interface og I-buttons eller temperaturfølere). Jeg har også fået et par stykker gennem tiden, men sidst jeg skulle bruge en var der lukket for det varme vand, så jeg måtte købe en hos Farnell tror jeg :o)

Reply to
Allan Soerensen