Pozdrav svima,

radim neki ureF0%aj za sebe i pala mi na pamet zgodna ideja ali ne znam =
kak  =

da ju izvedem

imam izvor napajanja DC 12v pa regulator voltaBE%e i "vruE6%u" BE%icu

momentalno grijem BE%icu sa 3V, ampere nisam mjerio ali nekih 1A +/- mog=
u  =

izmjeriti toE8%no ako je potrebno...

rado bi sloBE%io da imam neki alarm ako pukne BE%ica ... da se upali nek=
i  =

buzzer ili relay

sad isprobavam sa 3v al ako je moguE6%e da nisam vezan za tih 3v moBE%da=
 bi u  =

nekom sluE8%aju iB9%lo i do 12V
i koj amper viB9%e ...

ima ko kakvu ideju ... misao vodilju??

hvala

Re: Senzor prolaska struje - ideja ??
On 8.8.2018. 0:36, DK wrote:
Quoted text here. Click to load it

Quoted text here. Click to load it

Quoted text here. Click to load it


Quoted text here. Click to load it

Quoted text here. Click to load it



Quoted text here. Click to load it
reed relay

---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus


Re: Senzor prolaska struje - ideja ??
On 8.8.2018. 0:36, DK wrote:
Quoted text here. Click to load it

Quoted text here. Click to load it

Quoted text here. Click to load it


Quoted text here. Click to load it

Quoted text here. Click to load it



Quoted text here. Click to load it
reed relay

---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus


Re: Senzor prolaska struje - ideja ??


Quoted text here. Click to load it


Quoted text here. Click to load it

Quoted text here. Click to load it

Najjednostavnije zatvori strujni krug te zice koju grijes (i) preko SPDT
releja. Alarm spojis na NO kontakt, tako da dokle god strujni krug nije
prekinut i relej vodi nema kontakta, ali kada se zica prekine relej vraca u
NO poziciju i aktivira alarm (koji je naravno na bateriju ili barem s druge
strane i drugog napajanja; jer ako vuces napajanje alarma pored grijuce
zice, onda ono sto je presjeklo originalnu grijucu zicu ce vjerojatno
presjeci i to napajanje)





Ako ides dikretno kroz relej onda je struja ogranicena internim otporom
releja (i vece snage su naravno glomaznije skuplje):
+VCC ----grijuca-zica-------------- relej ---- GND

Quoted text here. Click to load it

A ako ti glavni grijuci krug treba biti velike snage,
uzmes hall effect sensor https://en.wikipedia.org/wiki/Hall_effect_sensor

npr. https://tinyurl.com/ybotpbep i vanjski detektiras s njim da li kroz
zicu tece struja (jer prolazak struje kroz zicu generira magnetno polje -
ovisnosti o osjetljivosti senzora, pogotovo ako nisu velike snage mozda ces
trebati dio grijuce zice namotati oko zeljezne jezgre da dobijes znacajno  
jace magnetno polje)


--  
Opinions above are GNU-copylefted.

Re: Senzor prolaska struje - ideja ??
On 09/08/18 13:20, Matija Nalis wrote:
Quoted text here. Click to load it
ili relay
 >









Re: Senzor prolaska struje - ideja ??
Prvo sam isprobao sa SPDT relejom sli ne radi,
relej se ukljuE8%i ali kroz njega ne prolazi dosta struje za troB9%ilo
probao sam sa Omron G2R-14-DC12
https://hr.mouser.com/ProductDetail/Omron-Electronics/G2R-14-DC12?qs3D%H=
DDQUw%2F3Phrubqzqk1%2FGww%3D%3D

evo detaljnije
napajanje je punjaE8% za akumulator 12v 10a
neki mali ebay regulator napona do 2a (kad nema troB9%ila napon sam stav=
io  =

na 3,2v kad stavim
troB9%ilo napon padne na 2,6v i vuE6%e 1,2a)
tom kombinacijom sam dobio idealno grijanje BE%ice

a ta vruE6%a BE%ica je u jednoj cjevE8%ici pa ju ne vidim i zato bi mi t=
rebao  =

neki alarm ako pukne)

E8%itam sve vaB9%e savjete ... sutra E6%u probati sa reed relejom pa jav=
im  =

rezultat
ako ne uspije idem dalje po vaB9%im savjetima...



Dana Thu, 09 Aug 2018 13:20:46 +0200, Matija Nalis  =


Quoted text here. Click to load it

mogu
neki
DT
e

 =

Quoted text here. Click to load it
e
da bi  =

Quoted text here. Click to load it
m
sor
oz
e -
Quoted text here. Click to load it
a  =

Quoted text here. Click to load it
jno

Re: Senzor prolaska struje - ideja ??

Pozdrav svima,


da ju izvedem







buzzer ili relay





ima ko kakvu ideju ... misao vodilju??

hvala

Najjeftiniji solid state sklop od par kuna bi izgledao ovako:
http://free-zg.t-com.hr/paramedia/download/indikacija.jpg

Kad se na otporu 1 ohm pojavi struja veca od 0,6A provede neki najjeftiniji  

Buzer se moze zamjeniti led diodom preko otpornika 0,5k
sa dva tranzistora moze se napravit da buzer pisti kada struje nema a ne  



Re: Senzor prolaska struje - ideja ??
ako mi ne uspije sa reed relejom budem probao sa npn tranzistorom,
jel bi 2SD879 NPN 30V 3A 0.75W 200MHz  bio ok?

i sad imam "muziE8%ku BE%elju" ;-)
jel moBE%e shema ako imaB9% volje da:
- kad BE%ica grije da svjetli npr. zelena dioda
- kad BE%ica pukne gasi se zelena i upali crvena ledica + buzer

hvala




Dana Thu, 09 Aug 2018 19:24:23 +0200, Petar BjelE8%iE6%  =


Quoted text here. Click to load it

m kak
ogu
eki
da bi u
Quoted text here. Click to load it

ne  =

Quoted text here. Click to load it

Re: Senzor prolaska struje - ideja ??
vjerojatno je bitno:
kad nema BE%ice regulator je na 3,2v
kad grijem BE%icu napon padne na 2,6v i vuE6%e 1,2a



je:

Quoted text here. Click to load it


am  =

Quoted text here. Click to load it

mogu
neki
da bi  =

Quoted text here. Click to load it

  =

Quoted text here. Click to load it

Re: Senzor prolaska struje - ideja ??
On 09/08/18 21:53, DK wrote:

Quoted text here. Click to load it

Quoted text here. Click to load it








http://www.falstad.com/circuit/



struje, pa ti zato umjesto 600 mV (3,2 V - 2,6 V = 600 mV) pad napona  









$ 1 0.000005 10.20027730826997 50 5 43
v 112 336 112 80 0 0 40 3.2 0 0 0.5
r 464 80 464 224 0 2.65
t 240 192 208 192 0 1 -2.2747534613779403 0.12361447501812876 100
w 208 208 208 336 0
w 320 224 320 336 0
t 352 208 320 208 0 1 0.49829092508240863 0.6219054002591385 100
r 320 336 416 336 0 1
w 416 336 464 336 0
w 416 208 416 336 0
r 352 208 416 208 0 5000
r 320 192 240 192 0 10000
x 128 231 164 234 4 14 3.2\sV
w 112 80 208 80 0
w 208 80 320 80 0
w 320 80 464 80 0
w 112 336 208 336 0
w 208 336 320 336 0
162 208 128 208 176 1 2.1024259 1 0 0 0.01
x 142 109 184 112 4 14 zujalo
x 143 157 189 160 4 14 Crveni
x 153 171 181 174 4 14 LED
r 208 128 208 80 0 8
x 146 126 180 129 4 14 (8\s?)
r 320 80 320 128 0 470
162 320 128 320 192 1 2.1024259 0 1 0 0.01
x 344 151 389 154 4 14 Zeleni
x 345 167 373 170 4 14 LED
s 464 224 464 336 0 0 false
368 464 336 528 336 0 0
x 506 266 566 269 4 14 Klikni\sna


x 503 315 583 318 4 14 strujni\skrug
o 27 64 0 4099 0.0000762939453125 1.6 0 2 27 3


Re: Senzor prolaska struje - ideja ??

i zujala.




Re: Senzor prolaska struje - ideja ??
sorry Luka dok si ti sve ovo osmislio u meC4%91uvremenu sam lupio onaj =
post  =

poslje a da nisam vidio
ovo tvoje

nisam baC5%A1 neki elektroniC4%8Dar(strojar sam) ... imam neke osnove =
i sve iznad  =

toga mi je SF i google
prouC4%8Dim i ovo tvoje pa valjda C4%87e nekaj proraditi


Dana Fri, 10 Aug 2018 01:40:31 +0200, Luka C4%86avara  =


Quoted text here. Click to load it
 izmeC4%91u nje  =

Quoted text here. Click to load it

Re: Senzor prolaska struje - ideja ??
duga ljetna noE6% pa googlam i googlam....
deE8%ki a ovo:
https://www.ebay.com/itm/1pcs-20A-range-Current-Sensor-Module-ACS712/201=
414894436?epid3D%1046171805&hash3D%item2ee5436364%3Ag%3Ae70AAMXQWzNSkEWZ=
&_sacat3D%0&_nkw3D%Current+Sensor&_from3D%R40&rt3D%nc&_trksid3D%m570.l13=
13&LH_TitleDesc3D%0

ili neki od drugih ebay + current sensor

na ovome navedenome za primjer na rednu stezaljku stavim da proF0%e 12v+=
  =

prije
regulatora, senzoru dam vcc 5v+ i gnd 5v-
i ostaje onaj OUT - koji je namjenjen za arduino

jel ima koja jednostavna caka(sklop-shema) da pojaE8%a(prepozna) taj OUT=
 i  =

da okine npr 12v relej
spdt(koji imam) i svi problemi rjeB9%eni ... ?




je:

Quoted text here. Click to load it
a  =

Quoted text here. Click to load it


nam  =

Quoted text here. Click to load it
u
 mogu
Quoted text here. Click to load it
 neki
Quoted text here. Click to load it
da  =

Quoted text here. Click to load it

a  =

Quoted text here. Click to load it

Re: Senzor prolaska struje - ideja ??

vjerojatno je bitno:



-----------------

tim naponima ne mogu ispunit "muzicku zrlju"
to je granica na kojoj ledice svijetle.
pitanje da li i buzzer hoce radit.

predlazem veci napon, recimo 12v

https://www.ebay.com/itm/New-Plug-Adapter-AC100-240V-To-DC-12V-2A-Power-Supply-For-3528-5050-Strip-LED-EU/252436004023?hash=item3ac65bbcb7%3Ag%3Ab4EAAOSwdIFXyPe1&_pgn=2&_sacat=0&_nkw=dc+power+supply+12v&_from=R40&rt=nc
i strujno ogranicenje
znaci 12v na sklop koji struju ogranici na 1,2A.
Time ce i napon na zici grijalice biti 2,6v kad je zica spojena,
a 12v kad zica nije spojena.
sklop koji to bez zagrijavanja zna odradit je ovo:

https://www.ebay.com/itm/LM2596-DC-DC-Step-down-Adjustable-CC-CV-Power-Supply-Module-Converter-LED-driver/400440730939?hash=item5d3c20a53b%3Ag%3AqFgAAOSw-KFXdjga&_sacat=0&_nkw=step+down+cc+cv&_from=R40&rt=nc&_trksid=m570.l1313

uz to on ce transformirat i struju, pa nece vuc 1,2A na 12V nego dosta  
manje, reda 400mA.

vec ima 3 diode koje su u biti ispunjenje muzicke zelje.
jedna svijetli kad se spoji grijac odnosno ne svijetli kada je u prekidu
druga svijetli kad napon dosegne podesenu vrijednost

procedura pri prvom ukljucenju
-spojiti 12v adapter i regulator
- podesiti izlazni napon bez grijaca na oko 3-4v
- spojiti zicu grijaca
- podesiti struju grijaca na 1,2A
tada ce podesen napon pasti na 2,6v


Re: Senzor prolaska struje - ideja ??
ok, hvala
imam 12v 2a adapter jedino moram naruE8%iti taj LM2596 converter

probao sam danas sa reed relejom i ne radi, relej radi ako pribliBE%im  =

magnet ali ono sa motanjem BE%ice oko njega ne radi sigurno jer je prema=
li  =

B9%trom...

no na taj sklop sam stavio mali led voltmetar i sad vidim ako je napon  =

2,6v BE%ica je ok ako je
3,2v BE%ica je pukla i to je ok
no ja bi neki alarm, ako nisam baB9% pored toga da bipka-zuji ako je BE%
ica  =

pukla.

i evo nova ideja - ako nije komplicirano za napravit??

jel ima nekaj da "skuBE%i" ga je napon veE6%i od 3v i da upali zujalicu =
ili  =

joB9% bolje
da mi okine 5v ili 12v relej ... ako je manji od 3v onda ne radi nikaj

a "muziE8%ka" je da tu max. voltaBE%u mogu mjenjati nekim potenciometrom=

jer ovo kaj radim je u eksperimentalnoj fazi pa E6%u moBE%da staviti  =

duBE%u-kraE6%u grijaE8%u BE%icu pa se
samim tim i volti mjenjaju.

e to bi bilo idealno...

sorry kaj vas davim ;-)



Dana Fri, 10 Aug 2018 21:47:01 +0200, Petar BjelE8%iE6%  =


Quoted text here. Click to load it

r-Supply-For-3528-5050-Strip-LED-EU/252436004023?hash3D%item3ac65bbcb7%3=
Ag%3Ab4EAAOSwdIFXyPe1&_pgn3D%2&_sacat3D%0&_nkw3D%dc+power+supply+12v&_fr=
om3D%R40&rt3D%nc
Quoted text here. Click to load it
-Supply-Module-Converter-LED-driver/400440730939?hash3D%item5d3c20a53b%3=
Ag%3AqFgAAOSw-KFXdjga&_sacat3D%0&_nkw3D%step+down+cc+cv&_from3D%R40&rt3D%
nc&_trksid3D%m570.l1313
Quoted text here. Click to load it
  =

Quoted text here. Click to load it
du

Re: Senzor prolaska struje - ideja ??
:-))))
mislim da je to to kaj traBE%im:
https://www.ebay.com/itm/Voltage-Monitor-Volt-Test-Relay-Switch-Control-=
Board-Module-DC-12V-Tester-A9Z3/252640285670?hash3D%item3ad288d3e6%3Ag%3=
AtswAAOSwd%7ERZU31a&_sacat3D%0&_nkw3D%Voltage+relay&_from3D%R40&rt3D%nc&=
_trksid3D%m570.l1313

samo ko bu to tipkal svaki put nanovo kad malo je u funkciji malo nije
tak da i dalje stoji upit iz prethodnog posta.




je:

Quoted text here. Click to load it
  =

Quoted text here. Click to load it
mali  =

Quoted text here. Click to load it
  =

Quoted text here. Click to load it
ica  =

Quoted text here. Click to load it
u ili  =

Quoted text here. Click to load it

om



er-Supply-For-3528-5050-Strip-LED-EU/252436004023?hash3D%item3ac65bbcb7%=
3Ag%3Ab4EAAOSwdIFXyPe1&_pgn3D%2&_sacat3D%0&_nkw3D%dc+power+supply+12v&_f=
rom3D%R40&rt3D%nc
Quoted text here. Click to load it
r-Supply-Module-Converter-LED-driver/400440730939?hash3D%item5d3c20a53b%=
3Ag%3AqFgAAOSw-KFXdjga&_sacat3D%0&_nkw3D%step+down+cc+cv&_from3D%R40&rt3D%
nc&_trksid3D%m570.l1313
Quoted text here. Click to load it
a  =

Quoted text here. Click to load it
idu

Re: Senzor prolaska struje - ideja ??


On 08/10/2018 10:40 PM, DK wrote:




Quoted text here. Click to load it

Za to ti je najbolja Petrova ideja sa strujnim izvorom koji daje  
konstantnu podesenu struju.
Onda se mozes igrati s duzinom zice bez ikakvih naknadnih podesavanja.

Koje napone imas na raspolaganju?


--  
Branko Vasiljev:
Vise se NIkada Nitko NECE Na Softveru
We've slightly trimmed the long signature. Click to see the full one.
Re: Senzor prolaska struje - ideja ??

ok, hvala





da mi okine 5v ili 12v relej ... ako je manji od 3v onda ne radi nikaj
------------------------


mislim da je to zelena led diodica.

koliko se sjecam mikro ledice su gore, jedna zasvijetli cim je sklop na  
naponu,

vrijednost.

naime taj sklop sluzi za punjenje baterija, i kad se upali zelena,
baterija je napunjena, odnosno napon je dosao do vrijednosti koja je  
podesena trimerom.
dakle ti taj trimer trebas podesiti da se ledica pali na 3v.

zato su tri ona plava trimera
jednim se podesava izlazni napon,drugim struja, a trecim napon indikacije  
napunjenosti.

Osim toga ako ti izlazni napon podesis na 2,6v, i struju na 1,2A struja zice  
nece otic u ne dopustenu vrijednost.

paralelno toj smd led diodici mozes dodat relej, naravno preko otpornika i  
tranzistora,
a mozda cak i direktno spojit 5v relej, nisam probao. neki mali relej trosi  
isto ko i ledica.


Re: Senzor prolaska struje - ideja ??
imam sve napone(ispravljaE6%e) na raspolaganju...5,12,24 32v

sad sam zamjenio izvor, stavio sam ispravljaE8% 12v 2a i nemam viB9%e pa=
da  =

napona kad spojim vruE6%u BE%icu
sad je konstantno 3,2v

naruE8%io sam i onaj dc converter pa sad kad stigne...

nego da pitam jel smijem u seriju spojiti vruE6%u BE%icu i elektromagnet=
?




Dana Sat, 11 Aug 2018 10:12:25 +0200, Petar BjelE8%iE6%  =


Quoted text here. Click to load it

u ili

a  =

Quoted text here. Click to load it
nu  =

Quoted text here. Click to load it


a  =

Quoted text here. Click to load it
ka  =

Quoted text here. Click to load it
 =

Quoted text here. Click to load it

Re: Senzor prolaska struje - ideja ??





sad je konstantno 3,2v





---------------


Mora biti motan zicom od pola kvadrata, odnosno promjera 0,7 mm ili debljom
inace ce se jako grijat.
On ce skinuti nesto napona ali to nije bitno jer izvor konstantne struje  
odrzava struju
bez obzira na otpor.  