Weird problem in Full wave (FW) bridge rectifier

I am working on implementation of FW bridge rectifier (without any filter). I am applying a sinusoidal input (1 Phase, +- 20, 60 Hz) to the bridge and measuring the voltage across the load resistance. When I am trying to dispaly the output waveform in a CRO, I am seeing only one half of the rectified waveform. I cross checked the individual diodes and I found that all are in perfect condition and working nice when using in HW rectifier mode. I want to know why I am seeing such a wierd results.

Reply to
dkmishra
Loading thread data ...

Where are you taking your ground reference from for the oscilloscope measurement?

Reply to
Greg Neill

YES

Reply to
dkmishra

"YES"? That's not a helpful response.

Reply to
Greg Neill

I resolved the problem. I was using input signal from the function generator of oscilloscope. I came to know that If you are feeding it a signal (~) that goes from oscilloscope ground to a positive voltage, there will be no negative part of the waveform when we measure it with oscilloscope. I then tried a transformer's output as the input and problem got resolved.

Reply to
deepak.mishra