I'd like to view the phase shift between currents and voltages testing various combinations of inductor, resistor and capacitor networks. The voltages should be no problem, but how can I display the currents? Do I have to have some kind of special probe?

TIA,

jules.

Reply to
Julian Barnes
Loading thread data ...

The simplest method is to put a small resistor in series with it, and measure the voltage drop. This is how a multimeter does it. This perturbs the circuit, of course--the voltage drop in the meter is called the "burden voltage", which is an apt name.

The second simplest is to use a current probe. I have a classic Tektronix P6042 that cost me $175 a few years back. It uses a combination of a current transformer and a Hall sensor to cover DC-50 MHz. Interestingly, clamping the probe over your signal wire adds series inductance. That causes a voltage drop at AC, almost like the DMM's burden voltage.

The most complicated is to build a transimpedance amplifier. This is basically an op amp inverter with the input resistor left off, so that you dump current straight into the inverting input. Ideally the op amp will force the voltage swing at its input to be small, so there's effectively much less burden voltage.

The circuit itself is conceptually simple--the parlour trick is getting it to work fast enough without oscillating when you hang a cable on its input.

I'd go with the resistor.

Cheers

Phil Hobbs

--
Dr Philip C D Hobbs 
Principal Consultant 
ElectroOptical Innovations LLC 
Optics, Electro-optics, Photonics, Analog Electronics 

160 North State Road #203 
Briarcliff Manor NY 10510 

hobbs at electrooptical dot net 
http://electrooptical.net
Reply to
Phil Hobbs

Yes, or, just put a R in series with your circuit and measure it with a secondary channel on the scope. Make sure the commons of your probes (BNC) are isolated on the scope. I know My cheap hand held Owen is. Not sure about the Rigol etc..

The other tool is to get yourself a low current DC clamp meter with a BNC or adapter to plug into your scope, I have 2 60 amps and 1 650 amp. Thinking of getting a much larger one, soon.

Jamie

Reply to
M Philbrook

you can. eg: VCR heads have in the past be re-purposed as current probes.

OTOH you may be able to add a low resistance and probe the voltage across that.

or you can spend real money on a current clamp probe.

formatting link

--
  \_(?)_
Reply to
Jasen Betts

If it's a current to ground, you can use an inverting op amp to generate a voltage signal (sometimes called 'transimpedance amp'). For some situations, a diamond transistor is a good sensor (and it'll be faster than most op amps); ground the 'base', current sense pin is the 'emitter', and output from 'collector' to ground through a resistor generates the voltage output.

If it is a current NOT to a midlevel power point (ground), the amplifier situation gets tricky, of course. Usually that means a sense resistor and an instrumentation amplifier are required. Sometimes, though, you can just connect two o'scope probes to the sense resistor and display the difference.

Reply to
whit3rd

What's the highest frequency you are hoping to look at. If you are staying well away from ~1MHz, and are good at making your own circuits. Then I took the TIA at the bottom of your post to be a sign that you should make a TIA (Trans Impedance Amp.) I made a little one of these on some copper clad to look at I-V curves of diodes and things. One opamp, bypass caps, some R's and a switch. I was going to post a picture, but it's "on loan" to someone.

George H.

Reply to
George Herold

Here's how I learned to do it, with a current sense resistor. The pcb* was built to accept scope probes and will work reasonably well up to 2 MHz.

Current and voltage waveform

You can add a few extra solder points for you resistor, as you see in green, I have add connections for a capacitor.

If you have more questions about the pcb or use, ask.

*The pcb was designed to plug in a piezo ceramic transducer, a variable inductor was adjusted until the current and voltage were in phase. Used for measuring specs of our transducers to then calculate drive inductor and transformer ratio. Mikek
Reply to
amdx

You got lots of advice, did you put it to positive use. Feedback is always nice.

Mikek

Reply to
amdx

Yes, thanks all. I'm going to go with the el-cheapo option and adopt the current sensing resistor suggestion. The current probes cost rather a lot, having taken a look at the prices online!

Reply to
Julian Barnes

Julian Barnes prodded the keyboard with:

Ought to pull a floppy disk drive apart. The heads make great current probes !

--
Best Regards: 
                      Baron.
Reply to
Baron

Are they position sensitive or can you pass a wire through them? ie, had do you make it work? Mikek

Reply to
amdx

Thanks for the input, what is your frequency of interest?

Mikek

Reply to
amdx

amdx prodded the keyboard with:

If you pull one apart you will see that it is a very tiny coil on a ferrite former. If you want to detect the current flowing in a pcb trace or wire you just align it with the trace and look at the output with a scope. A times 10 op amp helps since the output voltage is quite small.

--
Best Regards: 
                      Baron.
Reply to
Baron

yes, they are position sensitive. ok for relative-time measurments and fox-hunts, not much good for abolute measurements, or compating two different circuits.

for that you need a current transformer which goes right round the conductor.

--
  \_(?)_
Reply to
Jasen Betts

DC - 200Mhz primarily. I struggle with the physical challenges of anything much beyond 200!

Reply to
Julian Barnes

ooh! 200MHz, You better put a Curly Q as tight across a resistor as you can. Mount your scope probe right against your resistor.

Mikek

Reply to
amdx

I was just thinking that there must be current sensing circuitry in many SMPSs - the newer ones that provide for power factor correction anyway - so I guess it should be possible to obtain a suitable current sensing element for free from, say an old scrap computer for example?

Reply to
Cursitor Doom