Right. You only get millivolts out of these things.
John
Right. You only get millivolts out of these things.
John
If a load cell has a bridge of strain gages with sensibility of 2 mV/V, and I apply a V=5v, and the range of force is from 0 to100 Kg, is correct to say that with the max force applied the V difference should be 100 * 5
*2mV/V = 1V ?
-- No. What the 2mV/V means is that for every volt of excitation, the bridge will output 2 millivolts with the maximum rated mechanical
Nononononono unless it's given as 2mV/V/kg (which it isn't)
The output at maximum load will be 2mV * 5 = 10mV.
Paul Burke
Force is correctly measured in Newtons ! To use the old fashioned way of talking ... 1 N = 1 kgf ( not 1 kg ) = 1kg*9.81m/s. F = ma. Check the sensitivity spec.
Other than that, your calculation seems ok
Graham
ElectronDepot website is not affiliated with any of the manufacturers or service providers discussed here. All logos and trade names are the property of their respective owners.