Sort of a hybrid of a flyback and a sepic. I call it a skeptic converter.

I don't trust the efficiency calculation, especially when it goes over 100%.


Version 4
SHEET 1 1920 1092
WIRE 224 96 96 96
WIRE -48 144 -96 144
WIRE -16 144 -48 144
WIRE 96 144 96 96
WIRE 240 144 96 144
WIRE 320 144 240 144
WIRE 464 144 400 144
WIRE 528 144 464 144
WIRE 656 144 608 144
WIRE 912 144 864 144
WIRE 1056 144 992 144
WIRE 1152 144 1056 144
WIRE 1264 144 1216 144
WIRE 1312 144 1264 144
WIRE 1440 144 1392 144
WIRE 1456 144 1440 144
WIRE 1472 144 1456 144
WIRE -96 176 -96 144
WIRE 96 176 96 144
WIRE 240 240 240 144
WIRE 320 240 240 240
WIRE 464 240 464 144
WIRE 464 240 384 240
WIRE 1264 240 1264 144
WIRE 1312 240 1264 240
WIRE 1440 240 1440 144
WIRE 1440 240 1376 240
WIRE 1440 288 1440 240
WIRE 608 304 576 304
WIRE 656 304 656 144
WIRE 656 304 608 304
WIRE 736 304 656 304
WIRE 864 304 864 144
WIRE 864 304 800 304
WIRE -96 320 -96 256
WIRE 96 320 96 256
WIRE 656 336 656 304
WIRE 1056 336 1056 144
WIRE 864 352 864 304
WIRE 304 384 272 384
WIRE 400 384 368 384
WIRE 1440 400 1440 352
WIRE 656 432 656 416
WIRE -48 448 -96 448
WIRE -16 448 -48 448
WIRE 144 448 96 448
WIRE 272 448 272 384
WIRE 272 448 224 448
WIRE 304 448 272 448
WIRE 400 448 400 384
WIRE 400 448 368 448
WIRE 864 448 864 416
WIRE -96 480 -96 448
WIRE 1056 480 1056 416
WIRE 272 512 272 448
WIRE 304 512 272 512
WIRE 400 512 400 448
WIRE 400 512 368 512
WIRE 432 512 400 512
WIRE 560 512 512 512
WIRE 608 512 560 512
WIRE 96 576 96 448
WIRE 160 576 96 576
WIRE 272 576 272 512
WIRE 272 576 224 576
WIRE 304 576 272 576
WIRE 400 576 400 512
WIRE 400 576 368 576
WIRE 1056 592 1056 544
WIRE -96 624 -96 560
WIRE 400 624 368 624
WIRE 544 624 512 624
WIRE 656 624 656 528
WIRE 656 624 624 624
WIRE 368 656 368 624
WIRE 1120 672 1056 672
WIRE 1264 672 1200 672
WIRE 1312 672 1264 672
WIRE 1328 672 1312 672
WIRE 512 688 512 624
WIRE 512 688 400 688
WIRE 656 688 656 624
WIRE 96 704 96 576
WIRE 144 704 96 704
WIRE 320 704 144 704
WIRE 448 720 400 720
WIRE 464 720 448 720
WIRE 512 720 512 688
WIRE 1056 720 1056 672
WIRE 1264 736 1264 672
WIRE 368 768 368 752
WIRE 384 768 384 752
WIRE 384 768 368 768
WIRE 368 784 368 768
WIRE 512 816 512 784
WIRE 656 816 656 768
WIRE 400 832 368 832
WIRE 368 864 368 832
WIRE 1056 880 1056 800
WIRE 1264 880 1264 800
WIRE 656 896 400 896
WIRE 736 896 656 896
WIRE 864 896 816 896
WIRE 896 896 864 896
WIRE 96 912 96 704
WIRE 320 912 96 912
WIRE 96 928 96 912
WIRE 448 928 400 928
WIRE 480 928 448 928
WIRE 656 928 656 896
WIRE 368 976 368 960
WIRE 384 976 384 960
WIRE 384 976 368 976
WIRE 368 992 368 976
WIRE 96 1040 96 992
WIRE 656 1040 656 1008
FLAG 1456 144 VP
FLAG 656 816 0
FLAG 96 320 0
FLAG 608 304 DRAIN
FLAG 560 512 GATE
FLAG 864 448 0
FLAG 1056 592 0
FLAG 1056 880 0
FLAG 1312 672 EFF
FLAG 1264 880 0
FLAG 96 1040 0
FLAG 144 704 rc
FLAG 1440 400 0
FLAG 224 96 9V
FLAG 368 784 0
FLAG 400 624 9V
FLAG 448 720 0.2V
FLAG -96 320 0
FLAG -48 144 0.2V
FLAG 368 992 0
FLAG 400 832 9V
FLAG -96 624 0
FLAG -48 448 1.25V
FLAG 448 928 1.25V
FLAG 656 1040 0
FLAG 864 896 VP
FLAG 512 816 0
SYMBOL ind2 512 160 R270
WINDOW 0 -41 56 VTop 2
WINDOW 3 -53 53 VBottom 2
SYMATTR InstName L1
SYMATTR Value 5µ
SYMATTR Type ind
SYMATTR SpiceLine Rser=0.06
SYMBOL schottky 1152 160 R270
WINDOW 0 -41 30 VTop 2
WINDOW 3 -49 27 VBottom 2
SYMATTR InstName D1
SYMATTR Value 10MQ060N
SYMATTR Description Diode
SYMATTR Type diode
SYMBOL voltage 96 160 R0
WINDOW 0 60 48 Left 2
WINDOW 3 67 80 Left 2
WINDOW 123 0 0 Left 2
WINDOW 39 0 0 Left 2
SYMATTR InstName V2
SYMATTR Value 9
SYMBOL nmos 608 432 R0
WINDOW 0 -55 -55 Left 2
WINDOW 3 -101 -22 Left 2
SYMATTR InstName M1
SYMATTR Value Si7218DN
SYMBOL ind2 896 160 R270
WINDOW 0 -32 56 VTop 2
WINDOW 3 -41 57 VBottom 2
SYMATTR InstName L2
SYMATTR Value 5µ
SYMATTR Type ind
SYMATTR SpiceLine Rser=0.06
SYMBOL res 528 496 R90
WINDOW 0 -15 56 VBottom 2
WINDOW 3 46 56 VTop 2
SYMATTR InstName R3
SYMATTR Value 10
SYMBOL res 1296 160 R270
WINDOW 0 -38 31 VTop 2
WINDOW 3 -11 86 VBottom 2
SYMATTR InstName R6
SYMATTR Value 1m
SYMBOL cap 1376 224 R90
WINDOW 0 68 59 VBottom 2
WINDOW 3 42 -8 VTop 2
SYMATTR InstName C3
SYMATTR Value 50m
SYMBOL res 304 160 R270
WINDOW 0 -37 24 VTop 2
WINDOW 3 -11 88 VBottom 2
SYMATTR InstName R8
SYMATTR Value 1m
SYMBOL cap 384 224 R90
WINDOW 0 71 54 VBottom 2
WINDOW 3 43 0 VTop 2
SYMATTR InstName C6
SYMATTR Value 50m
SYMBOL res 1040 320 R0
WINDOW 0 59 38 Left 2
WINDOW 3 58 74 Left 2
SYMATTR InstName R9
SYMATTR Value 500
SYMBOL cap 1040 480 R0
WINDOW 0 -46 35 Left 2
WINDOW 3 -50 68 Left 2
SYMATTR InstName C7
SYMATTR Value 30p
SYMBOL bv 1056 704 R0
WINDOW 3 -110 247 Left 2
WINDOW 0 -83 97 Left 2
SYMATTR Value V= LIMIT (0, 100 * I(R6) * V(VP)  /  ( I(R8) * 9 ), 120)
SYMATTR InstName B1
SYMBOL res 1216 656 R90
WINDOW 0 70 60 VBottom 2
WINDOW 3 78 61 VTop 2
SYMATTR InstName R1
SYMATTR Value 1K
SYMBOL cap 1248 736 R0
WINDOW 0 -37 63 Left 2
WINDOW 3 -43 94 Left 2
SYMATTR InstName C2
SYMATTR Value 10n
SYMBOL Digital\schmtinv 160 512 R0
SYMATTR InstName A1
SYMATTR Value2 Vhigh=5 Vt=2.5 Vh=0.5
SYMATTR SpiceLine Td=5n
SYMBOL cap 80 928 R0
WINDOW 0 44 60 Left 2
WINDOW 3 37 92 Left 2
SYMATTR InstName C4
SYMATTR Value 500p
SYMBOL res 128 464 R270
WINDOW 0 88 58 VTop 2
WINDOW 3 74 57 VBottom 2
SYMATTR InstName R4
SYMATTR Value 2K
SYMBOL Digital\schmtinv 304 448 R0
SYMATTR InstName A2
SYMATTR Value2 Vhigh=5 Vt=2.5 Vh=1
SYMATTR SpiceLine Td=5n
SYMBOL Digital\schmtinv 304 384 R0
SYMATTR InstName A3
SYMATTR Value2 Vhigh=5 Vt=2.5 Vh=1
SYMATTR SpiceLine Td=5n
SYMBOL Digital\schmtinv 304 512 R0
SYMATTR InstName A4
SYMATTR Value2 Vhigh=5 Vt=2.5 Vh=1
SYMATTR SpiceLine Td=5n
SYMBOL Digital\schmtinv 304 320 R0
SYMATTR InstName A5
SYMATTR Value2 Vhigh=5 Vt=2.5 Vh=1
SYMATTR SpiceLine Td=5n
SYMBOL cap 1424 288 R0
WINDOW 0 -70 43 Left 2
WINDOW 3 -64 77 Left 2
SYMATTR InstName C5
SYMATTR Value 4µ
SYMBOL res 640 320 R0
WINDOW 0 47 70 Left 2
WINDOW 3 41 102 Left 2
SYMATTR InstName R7
SYMATTR Value 1m
SYMBOL res 640 672 R0
WINDOW 0 70 52 Left 2
WINDOW 3 75 86 Left 2
SYMATTR InstName R10
SYMATTR Value 0.2
SYMBOL Comparators\LT1011 368 704 M0
SYMATTR InstName U1
SYMBOL voltage -96 160 R0
WINDOW 0 63 53 Left 2
WINDOW 3 61 85 Left 2
WINDOW 123 0 0 Left 2
WINDOW 39 0 0 Left 2
SYMATTR InstName V1
SYMATTR Value 0.2
SYMBOL Comparators\LT1011 368 912 M0
SYMATTR InstName U2
SYMBOL voltage -96 464 R0
WINDOW 0 61 45 Left 2
WINDOW 3 54 83 Left 2
WINDOW 123 0 0 Left 2
WINDOW 39 0 0 Left 2
SYMATTR InstName V3
SYMATTR Value 1.25
SYMBOL res 640 912 R0
WINDOW 0 -56 37 Left 2
WINDOW 3 -57 71 Left 2
SYMATTR InstName R5
SYMATTR Value 1K
SYMBOL res 832 880 R90
WINDOW 0 69 56 VBottom 2
WINDOW 3 74 56 VTop 2
SYMATTR InstName R11
SYMATTR Value 37.4K
SYMBOL cap 800 288 R90
WINDOW 0 0 32 VBottom 2
WINDOW 3 32 32 VTop 2
SYMATTR InstName C1
SYMATTR Value 2µ
SYMBOL res 640 608 R90
WINDOW 0 65 54 VBottom 2
WINDOW 3 71 54 VTop 2
SYMATTR InstName R2
SYMATTR Value 1K
SYMBOL cap 496 720 R0
WINDOW 0 54 32 Left 2
WINDOW 3 43 63 Left 2
SYMATTR InstName C8
SYMATTR Value 300p
SYMBOL schottky 880 416 R180
WINDOW 0 42 2 Left 2
WINDOW 3 -44 -85 Left 2
SYMATTR InstName D2
SYMATTR Value 10MQ060N
SYMATTR Description Diode
SYMATTR Type diode
TEXT 1184 576 Left 2 !.tran 0 4m 0 10n uic
TEXT 1168 480 Left 2 ;SKEPTIC CONVERTER
TEXT 1208 528 Left 2 ;JL  July 3  2013
TEXT 688 128 Left 2 !K L1 L2 0.99
TEXT 192 624 Left 2 ;74HC14
TEXT 160 504 Left 2 ;OSC
TEXT 736 176 Left 2 ;1:1
TEXT 160 808 Left 2 ;USE LM393



--  

John Larkin                  Highland Technology Inc
www.highlandtechnology.com   jlarkin at highlandtechnology dot com    

We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
On Wed, 03 Jul 2013 21:53:35 -0700, John Larkin

Quoted text here. Click to load it

Interesting equation for efficiency ?>:-}
        
                                        ...Jim Thompson
--  
| James E.Thompson                                 |    mens     |
| Analog Innovations                               |     et      |
We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
John Larkin wrote:
Quoted text here. Click to load it

Patent it, quickly! :-)

The reason for that are the very large caps C3 and C6 which are not in
your efficiency calc. If you take those out or set them to 50pF or
something, it's all in the green. Peaks at 92% on the ramp-up but then
efficiency really goes to pots as the output voltage comes up.

[SPICE file]

--  
Regards, Joerg

http://www.analogconsultants.com/

Re: another goofy boost converter architecture
wrote:

Quoted text here. Click to load it

That sure is a strange looking expression for efficiency.  Where did
that come from?  Wouldn't efficiency be a long average of output power
divided by a long average of input power.
        
                                        ...Jim Thompson
--  
| James E.Thompson                                 |    mens     |
| Analog Innovations                               |     et      |
We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
Jim Thompson wrote:
Quoted text here. Click to load it

Yeah, technically you have to integrate. But with switchers it does not
require long averages if one does not use large caps in there. I found
that my simple non-integrated values jibe quite well with the circuit
later once it comes from the assemblers.

--  
Regards, Joerg

http://www.analogconsultants.com/

Re: another goofy boost converter architecture
wrote:

Quoted text here. Click to load it

Still a weird equation.  Who dreamt (or nightmared) that?

In PSpice Probe (post-processor) one uses the "avgx" function and
average over a cycle (if you like).
        
                                        ...Jim Thompson
--  
| James E.Thompson                                 |    mens     |
| Analog Innovations                               |     et      |
We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
wrote:

Quoted text here. Click to load it

Power_out / Power_in sounds like "efficiency" to me.



Re: another goofy boost converter architecture
On Thu, 04 Jul 2013 12:18:24 -0700, John Larkin

Quoted text here. Click to load it

But I*V is _instantaneous_ power, not average over a cycle, or over
some longer period.
        
                                        ...Jim Thompson
--  
| James E.Thompson                                 |    mens     |
| Analog Innovations                               |     et      |
We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
On Thu, 04 Jul 2013 13:32:01 -0700, Jim Thompson

Quoted text here. Click to load it

Makes no sense. I average it over the period of interest.

Quoted text here. Click to load it

My numerator and denominator are what the 9 volt supply has to furnish
and what the load (a cap, in this case) absorbs. I want to see
efficiency as a function of time, during charging, because that's what
I want to see.  

The filters on the input and output current make them plot nicely.
Real-life power supplies do, after all, have input and output bypass
caps. My customer's battery won't see the mosfet instantaneous
current; he cares about the current he can measure, and the total
energy he has to furnish, which is the data I'm generating.

I could add a bypass cap across the 9V source if that would make you
happy.  




Re: another goofy boost converter architecture
On Thu, 04 Jul 2013 14:11:11 -0700, John Larkin

Quoted text here. Click to load it

You totally missed (or evaded) the point.  Is anyone surprised?
        
                                        ...Jim Thompson
--  
| James E.Thompson                                 |    mens     |
| Analog Innovations                               |     et      |
We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
On Thu, 04 Jul 2013 17:19:39 -0700, Jim Thompson

Quoted text here. Click to load it

You never say anything concrete. And nobody is surprised.

Post a equation that you think reports efficiency.



Re: another goofy boost converter architecture
On Thu, 04 Jul 2013 18:14:08 -0700, John Larkin

Quoted text here. Click to load it

I did already.  Wimp.  Wimp. Whine, Whine.
        
                                        ...Jim Thompson
--  
| James E.Thompson                                 |    mens     |
| Analog Innovations                               |     et      |
We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
On 7/4/2013 4:11 PM, John Larkin wrote:
Quoted text here. Click to load it

Well, John, make sure your "period of interest" includes energy returned  
as well as energy supplied.

John S


Re: another goofy boost converter architecture
wrote:

Quoted text here. Click to load it

What does that mean?




Re: another goofy boost converter architecture
On 7/4/2013 8:16 PM, John Larkin wrote:
Quoted text here. Click to load it

What is the load and the "period of interest"? (Your turn now).


Re: another goofy boost converter architecture
On 7/4/2013 8:16 PM, John Larkin wrote:
Quoted text here. Click to load it

I think I should back out of this thread. I do not understand your  
definition of efficiency because you have no load on your simulation. I  
always thought that efficiency was Pout/Pin. Since Pout is close to zero  
(steady state) your efficiency cannot be very good.

Good luck.




Re: another goofy boost converter architecture
On 7/4/2013 8:16 PM, John Larkin wrote:
Quoted text here. Click to load it

Well, sort of this...

Use the following for your behavioral source for efficiency:

V= 100 *idt( I(R6) * V(VP)  /  ( I(R8) * 9 ))/time

It does not go over 100%. If you see a flaw in the math, please ping me.

Cheers,
JohnS


Re: another goofy boost converter architecture
wrote:

Quoted text here. Click to load it

At time T in the sim, that gives the average of efficiency since
startup. That's not what I want to see; I want to see the "realtime"
efficiency vs time curve. If course, some amount of time averaging is
required to get a usable plot, which is why I have filtering.

Your equation has a gotcha too. 1 mw/1mw makes the same contribution
to the efficiency integral as 1w/1w, which doesn't seem fair to me.
The actual averaged efficiency might better be (integrated energy out)
/ (integrated energy in). That would be the ratio of two integrals,
not the integral of one ratio. But again, that's not what I want to
see.

There is no unambiguous, clearly right definition of efficiency here.
My equation is what I want to see.



Re: another goofy boost converter architecture
On Fri, 05 Jul 2013 17:20:19 -0700, John Larkin

Quoted text here. Click to load it

Your equation "clips" products greater than 120 or more negative than
zero.  What kind of gimmick is that?

The integral needs to encompass at least one cycle.  Your
"integration" is way short.

Unfortunately LTspice doesn't implement one of PSpice's Probe
niceties, AVGX... average over t=X.
        
                                        ...Jim Thompson
--  
| James E.Thompson                                 |    mens     |
| Analog Innovations                               |     et      |
We've slightly trimmed the long signature. Click to see the full one.
Re: another goofy boost converter architecture
On 7/5/2013 7:20 PM, John Larkin wrote:
Quoted text here. Click to load it

Okay.

ISTM that a better metric to determine how happy I would be with it, if  
it were mine, would be watt-seconds in the output capacitor divided by  
watt-seconds supplied by the source, calculated over the charging interval.

For curosity, I did that and I see that it puts 4.6 w*s into the output  
capacitor while using 5 w*s from the source. That would be about 92%  
efficient. Not bad.

Anyway, not my project, so have fun.