How can I surpress noise in an ADC board?

While I have only a 40MHz clock connected to a 10 bit ADC, nothing connected to the analog input sockets, the chip is Analog AD9218 (ADC chip) EVM board. On the LA, sampled outputs are 0~16 for one channel, -32~0 for the other channel (400 MHz timing mode). Is my board faulty?

According to my simulation in digital design, my sampled inputs (10 bits each) can not have noise higher than 1 LSB (flipping small number of bit 0 causes demodulation error).

Is the setup I have workable or croaked?

Reply to
Frank
Loading thread data ...

Terminate the inputs (don't leave them open) and try again perhaps?

Dave :)

Reply to
David L. Jones

What happens if you tie the inputs to ground rather than leaving them floating?

--
Greg
Reply to
Gregory C. Read

I took a look at the data sheet

For the noise question:

  1. The inputs need a low inpedance source. Someone already noted trying to tie the inputs to ground.

  1. The Sample and hold (as with all sample and holds) will mix any extraneous noise, regardless of the precautions taken in the silicon.

  2. A 10 bit converter usually has somewhere of the order of 8.5 ENOB (Effective number of bits)

  1. The output will definitely be flipping codes if the input is at the (current) threshold.

I would not expect the samples to be varying up and down too far, but...

The datasheet shows pretty superior performance, but you still have a limited differential input range of either 1 or 2V (depending on device). So 1 LSB equates to just under a millivolt for the 1V range. It's not hard to get a few millivolts of noise onto an analog signal. Signal shielding and low inpedance drive are two of the various tricks we have up our sleeves.

Keep in mind (you say you are demodulating a signal) that the various errors on the A-D section can get you +/-18LSB (worst case ) offset error, up to 8% fullscale (for 1V, that's 80mV) gain error and differential nonlinearity (variances between the encoding levels) of up to 1LSB. This all in addition to the irreducible (well, at the Nyquist limit) +/-0.5LSB quantization error. Note that differential nonlinearity acts as a curvature on the conversion curve which we would like to be a perfectly straight line.

For the immediate question, for an unterminated input in a noisy environment (and most things are noisy at the millivolt level), I don't think you are seeing anything really unexpected. It can be dealt with though.

Cheers

PeteS

Reply to
PeteS

1) Turn on a an autoranging digital multimeter with the test leads dangling. You will probably see the reading bounce around from +/-5 to 10 mV. Now twist the leads and short the ends. You probably won't see more than 1 mV that way. 2) Put your finger on your sound system's input terminal with nothing else connected to it. Set the volume control to a normal level.

Either procedure will demonstrate the need for thought and care with analog signals. I'm sure you knew that, but it's easy to overlook.

Jerry

--
Engineering is the art of making what you want from things you can get.
¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
Reply to
Jerry Avins

ENOB is relative to the maximum signal level and isn't much help if a measurement of system noise is desired.

I might tie the >Frank wrote:

Reply to
John Herman

that

operation.

the

Yeah, it seems a good idea to terminate the ADC input with 50 Ohm resister, I will try that with one 50Ohm termination.

my DAC output is said to terminate with a 50Ohm output resistance, while when I connect the output with a plain cable into oscilloscope with 50 Ohm termination, the oscilloscope showed amplitude of only 100mV when digital outputs are in full swing. When digital outputs are zeros, the oscilloscope shows a 50mV peak to peak random noise.

Reply to
Frank

That doesn't sound very promising. You've set it up for 20mA peak output so your outputs in full swing should be varying between +/- 20 mA ? Through a

1:1 output transformer and into a 50 ohm termination I would have expected close to 2V peak to peak.
Reply to