Flash protection

Do you have a question? Post it now! No Registration Necessary

Translate This Thread From English to



Hi
I want to debug a program with Metrowerks CodeWarrior and load it on a
MC9S12DT128B with P&E USB Multilink.
When i want to download it, following messages appear in the command
window:


!Command < attributes CACHESIZE 1000
!bckcolor 50331647
!font 'Courier New' 9 BLACK
!AUTOSIZE on
!ACTIVATE Data:2 Command Procedure Data:1 Source Register Assembly
Memory
done C_layout.hwl

Loading Target ...
SETCOMM DRIVER NOPROTOCOL NOPERIODICAL ""
SETCOMM COMPORT NONE
executing .\cmd\p&e_icd_startup.cmd

!// At startup the commands written below will be executed
ICD-12 ready
done .\cmd\p&e_icd_startup.cmd

Startup command file correctly executed.
executing .\cmd\p&e_icd_preload.cmd

!// Before load the commands written below will be executed
ICD-12 ready
done .\cmd\p&e_icd_preload.cmd

Preload command file correctly executed.
FP: FLASH parameters loaded for MC9S12DT128B_V10 from C:\Program
Files\Metrowerks\CodeWarrior CW12_V3.1\prog\FPP\mcu03DA.fpp
executing .\cmd\p&e_icd_reset.cmd

!// After reset the commands written below will be executed
done .\cmd\p&e_icd_reset.cmd

Reset command file correctly executed.
FP: FLASH parameters loaded for MC9S12DT128B_V10 from C:\Program
Files\Metrowerks\CodeWarrior CW12_V3.1\prog\FPP\mcu03DA.fpp

      MCU clock speed: 8054000 Hz
Block Module Name      Address Range   Status
   0  EEPROM            2000 -  27FF   Blank - Unselected
   1  FLASH_4000        4000 -  7FFF   Blank - Unselected
   2  FLASH_C000        C000 -  FFFF   Blank - Unselected
   3  PAGED           388000 -3FBFFF   Blank - Unselected

FP: The UNPROTECT command is not available for the EEPROM flash module
3D%> Skipped.

FP: The UNPROTECT command is not available for the FLASH_4000 flash
module 3D%> Skipped.

FP: The UNPROTECT command is not available for the FLASH_C000 flash
module 3D%> Skipped.

FP: The UNPROTECT command is not available for the PAGED flash module
3D%> Skipped.
executing .\cmd\p&e_icd_vppon.cmd

!// Before programming the flash, the commands written below will be
executed
done .\cmd\p&e_icd_vppon.cmd

Vppon command file correctly executed.
executing .\cmd\p&e_icd_vppoff.cmd

!// After programming the flash, the commands written below will be
executed
done .\cmd\p&e_icd_vppoff.cmd

Vppoff command file correctly executed.
FP: Arm FLASH for loading.
executing .\cmd\p&e_icd_vppon.cmd

!// Before programming the flash, the commands written below will be
executed
done .\cmd\p&e_icd_vppon.cmd

Vppon command file correctly executed.
executing .\cmd\p&e_icd_vppoff.cmd

!// After programming the flash, the commands written below will be
executed
done .\cmd\p&e_icd_vppoff.cmd

Vppoff command file correctly executed.
FP: FLASH disarmed.
executing .\cmd\p&e_icd_reset.cmd

!// After reset the commands written below will be executed
done .\cmd\p&e_icd_reset.cmd

Reset command file correctly executed.
executing C:\Konrad Blum\HC12\titi\bin\P&E_ICD.bpt

!savebp off
RESET
done C:\Konrad Blum\HC12\titi\bin\P&E_ICD.bpt

executing C:\Konrad Blum\HC12\titi\bin\P&E_ICD.mrk

!MARKPOINTS SAVE OFF
done C:\Konrad Blum\HC12\titi\bin\P&E_ICD.mrk

executing .\cmd\p&e_icd_postload.cmd

!// After load the commands written below will be executed
!// Show main function at startup
!FindProc main
done .\cmd\p&e_icd_postload.cmd

Postload command file correctly executed.

in>


So, the Flash and Eeprom is protected.
The program already worked on another print (a similar one)
Can anybody help me??

Greez KF6%nsi


Site Timeline