Hi I want to debug a program with Metrowerks CodeWarrior and load it on a MC9S12DT128B with P&E USB Multilink. When i want to download it, following messages appear in the command window:

!Command < attributes CACHESIZE 1000 !bckcolor 50331647 !font 'Courier New' 9 BLACK !AUTOSIZE on !ACTIVATE Data:2 Command Procedure Data:1 Source Register Assembly Memory done C_layout.hwl

Loading Target ... SETCOMM DRIVER NOPROTOCOL NOPERIODICAL "" SETCOMM COMPORT NONE executing .\cmd\p&e_icd_startup.cmd

!// At startup the commands written below will be executed ICD-12 ready done .\cmd\p&e_icd_startup.cmd

Startup command file correctly executed. executing .\cmd\p&e_icd_preload.cmd

!// Before load the commands written below will be executed ICD-12 ready done .\cmd\p&e_icd_preload.cmd

Preload command file correctly executed. FP: FLASH parameters loaded for MC9S12DT128B_V10 from C:\Program Files\Metrowerks\CodeWarrior CW12_V3.1\prog\FPP\mcu03DA.fpp executing .\cmd\p&e_icd_reset.cmd

!// After reset the commands written below will be executed done .\cmd\p&e_icd_reset.cmd

Reset command file correctly executed. FP: FLASH parameters loaded for MC9S12DT128B_V10 from C:\Program Files\Metrowerks\CodeWarrior CW12_V3.1\prog\FPP\mcu03DA.fpp

MCU clock speed: 8054000 Hz Block Module Name Address Range Status 0 EEPROM 2000 - 27FF Blank - Unselected 1 FLASH_4000 4000 - 7FFF Blank - Unselected 2 FLASH_C000 C000 - FFFF Blank - Unselected 3 PAGED 388000 -3FBFFF Blank - Unselected

FP: The UNPROTECT command is not available for the EEPROM flash module =3D> Skipped.

FP: The UNPROTECT command is not available for the FLASH_4000 flash module =3D> Skipped.

FP: The UNPROTECT command is not available for the FLASH_C000 flash module =3D> Skipped.

FP: The UNPROTECT command is not available for the PAGED flash module =3D> Skipped. executing .\cmd\p&e_icd_vppon.cmd

!// Before programming the flash, the commands written below will be executed done .\cmd\p&e_icd_vppon.cmd

Vppon command file correctly executed. executing .\cmd\p&e_icd_vppoff.cmd

!// After programming the flash, the commands written below will be executed done .\cmd\p&e_icd_vppoff.cmd

Vppoff command file correctly executed. FP: Arm FLASH for loading. executing .\cmd\p&e_icd_vppon.cmd

!// Before programming the flash, the commands written below will be executed done .\cmd\p&e_icd_vppon.cmd

Vppon command file correctly executed. executing .\cmd\p&e_icd_vppoff.cmd

!// After programming the flash, the commands written below will be executed done .\cmd\p&e_icd_vppoff.cmd

Vppoff command file correctly executed. FP: FLASH disarmed. executing .\cmd\p&e_icd_reset.cmd

!// After reset the commands written below will be executed done .\cmd\p&e_icd_reset.cmd

Reset command file correctly executed. executing C:\Konrad Blum\HC12\titi\bin\P&E_ICD.bpt

!savebp off RESET done C:\Konrad Blum\HC12\titi\bin\P&E_ICD.bpt

executing C:\Konrad Blum\HC12\titi\bin\P&E_ICD.mrk

!MARKPOINTS SAVE OFF done C:\Konrad Blum\HC12\titi\bin\P&E_ICD.mrk

executing .\cmd\p&e_icd_postload.cmd

!// After load the commands written below will be executed !// Show main function at startup !FindProc main done .\cmd\p&e_icd_postload.cmd

Postload command file correctly executed.

in>

So, the Flash and Eeprom is protected. The program already worked on another print (a similar one) Can anybody help me??

Greez K=F6nsi

Reply to
corrrado
Loading thread data ...